If you have a Sun host and existing SAN boot images that
are controlled by storage controllers, you can migrate these images
to image-mode virtual disks (VDisks) that are controlled by the SAN Volume Controller.
Perform the following steps to migrate your existing SAN
boot images:
- Shut down the host.
- Perform the following configuration changes on the storage
controller:
- Remove all the image-to-host mappings from the storage
controller.
- Map the existing SAN boot image and any
other disks that you want to present to the SAN Volume Controller.
- Zone one port of each host bus adapter
(HBA) to one of the SAN Volume Controller ports
that is associated with the I/O group for the target image-mode VDisk.
- Perform the following configuration changes on the SAN Volume Controller:
- Create an image-mode VDisk for the managed disk (MDisk)
that contains the SAN boot image. Use the MDisk unique
identifier to specify the correct MDisk.
- Create a host object and assign it to
the HBA port that you zoned to SAN Volume Controller port
in step 3.
- Map the image mode VDisk to the host. For
example, you might map the swap disk to the host with SCSI LUN ID
0.
- Map the swap disk to the host, if required. For
example, you might map the swap disk to the host with SCSI LUN ID
1.