There are limitations in switch zoning for the SAN Volume Controller and the EMC Symmetrix and Symmetrix DMX systems.
The SAN Volume Controller switch zone must include at least one target port on two or more fibre-channel adapters to avoid a single point of failure.
The EMC Symmetrix and Symmetrix DMX must be configured to present logical units (LUs) to all SAN Volume Controller initiator ports that are in the fabric zone.
Only SAN Volume Controller initiator ports that are LUN masked on the EMC Symmetrix or Symmetrix DMX controller should be present in the fabric zone.
You can connect a maximum of 16 EMC Symmetrix or Symmetrix DMX ports to the SAN Volume Controller cluster. There are no further special zoning requirements. Configurations that are setup to adhere to the requirements that are described in previous SAN Volume Controller releases are also supported, but should not be followed for new installations.