You must verify the SAN Volume Controller installation
after the installation has
completed.
This
task shows you how to verify the installation after you install the SAN Volume Controller in
the rack and connect it to the uninterruptible
power supply,
the storage area network (SAN), and the Ethernet.
Note: If at any point the
SAN Volume Controller does
not operate as described, see
MAP 5000: Start,
unless a different maintenance analysis procedure (MAP) is specified.
Perform the following steps to verify installation:
- Press the SAN Volume Controller power-control
button. Because the button is recessed, you might need a pointed device,
such as a screwdriver, to press the power-control button. Verify that
the green power LED is lit. If the LED is not illuminated, see MAP 5000: Start to
repair the problem.
Note: You do not need
to install any software. The node boots automatically.
Verify that the node is booting without error. If
it boots without error, either the Charging, Recovering,
or the Cluster: message is displayed in the first
line of the front-panel display.
- Press and hold the
select button for five seconds. The check light comes on and a display
test is performed. Check that all display cells light and that
a bar scrolls horizontally and vertically across the display. When
the display test is complete, the check light goes off and a button
test is started.
- Press the up, down,
left, and right buttons to verify that they are working. Figure 2 shows
four examples of what the front panel should display when you press
the buttons. After you finish testing the buttons, press and hold
the select button for five seconds to exit the test.
- If the Charging or Recovering message
is displayed on the front-panel display, press the select button to
switch to the menu. The menu continues to be displayed while you press
the buttons on the front panel. If you do not press any buttons within
60 seconds, the menu changes to display the charging progress. You
can switch the front-panel display to the menu at any time by pressing
the select button again.
- Press and release
the up button or down button until the Node: option
is displayed on the first line of the front-panel display.
- Verify that the node number that is displayed on the
second line of the front-panel display is the same as the node number
that is printed on the front panel of the node. Figure 3 shows
how the node number is displayed on the front panel. If the node number is not the same, contact the IBM® Support
Center.
- Press and release the up button or down button until
the Ethernet option is shown on the front-panel
display. The
second line of the front-panel display in Figure 4 shows
the message Inactive. This message indicates that, although
an Ethernet connection is available, it cannot yet be used.
- Press and release the up button or down button until
the FC Port-1 option shows in the display.
- Check whether the second line of the front-panel display
shows the message Active. If Active is
not shown on the second line, go to MAP 5600: Fibre-channel to repair the fault.
- Press and hold the down button.
- Press and release the select button.
- Release the down button. The operational speed of
the fibre-channel link is displayed. Use the cable connection table
that is provided by the customer to verify that the fibre-channel
link is operating at the expected speed. If the operational speed
does not match the expected speed, go to MAP 5600: Fibre-channel to
repair the fault.
- Press the select
button to return to the fibre-channel status display.
- Press the right button to display each port in turn
and ensure that the port is active and the speed is correct.
- If you want to select a language other than English,
perform the following steps:
- Press the up or down button until Select
Language? is
displayed.
- Press the select button.
- Press the left or right button until the required
language
is displayed.
- Press the select button.
If the
battery needed to be charged, the Charging or Recovering message
is replaced by the Cluster: message when the battery
is fully charged. The progress bar no longer displays. The installation
of the SAN Volume Controller hardware
is now complete. No software installation is required. Continue with
the instructions in the IBM System Storage® SAN Volume Controller
Software Installation and Configuration Guide to
create, if necessary, a new SAN Volume Controller cluster
and to add the nodes into a SAN Volume Controller cluster.