The diagsi command
is an administrative command that is provided to a DS6000 (1750) user who
has administrator or service authority. This command is used to enable a warm
start.

>>-diagsi-- -action--warmstart--+-storage_image_ID-+-----------><
'-" - "------------'
Parameters
Notes: - You must be in interactive mode to process this command. This command
cannot be initiated while in single shot mode or from a script.
- Only users with administrator or service authority are authorized to use
this command.
- The -action warmstart parameter allows you to collect microcode
data when you have a problem with your DS6000 storage unit.
- -action warmstart
- (Required) Specifies the administrative action to be performed.
- warmstart
- The -action warmstart parameter is restricted to the following
usage rules:
- Five minutes must pass before you can reissue the -action warmstart parameter.
- You cannot issue the -action warmstart parameter more than
10 times during a 24 hour period.
- storage_image_ID | -
- (Required) Accepts a fully qualified storage image ID. The storage image
ID consists of manufacturer, machine type, and serial number.
- If you specify the dash (-), this parameter information is automatically
supplied.
Example
Invoking
the diagsi commanddscli>diagsi
-action warmstart IBM.1750–68FA120
The
resulting outputDate/Time: Sun Aug 11 02:23:49 PST 2004 DS CLI Version: 5.0.0.0
DS: IBM.1750–68FA120
Warmstart on Storage Unit IBM.1750-68FA120 successfully completed