lssu

The lssu command displays a list of storage units in a storage complex. You can use this command to look at the status and other properties of each storage unit in the list.

Read syntax diagramSkip visual syntax diagram
>>-lssu--+-----+--+------------------+-------------------------->
         +- -s-+  '- -power--+-on--+-'   
         '- -l-'             '-off-'     

>--+----------------------------+------------------------------><
   +-storage_unit_ID--+-------+-+   
   |                  '-. . .-' |   
   '-" - "----------------------'   

Parameters

-s
(Optional) Displays storage unit IDs. You cannot use the -l and the -s parameters together.
-l
(Optional) Displays default output and remote mode with scheduled power-on and power-off times, and the storage unit description. You cannot use the -l and the -s parameters together.
-power on | off
(Optional) Displays only the storage units in the specified power state.
storage_unit_ID . . . | -
(Optional) Displays storage units with the specified storage unit IDs. A storage unit ID includes manufacturer, type, and serial number. You must separate multiple IDs with a space between each ID.
Note: You cannot specify ID ranges.
If you specify the dash (-), this parameter information is automatically supplied.

Example

For this command and all other DS CLI list commands, the results are shown in table format to provide clarity. The actual reports do not display as tables.

The following table represents the headers that are displayed on the output report that is associated with the lssu command using the -l parameter. A separate example is not shown for the 1750 because the information is the same for the 2107 and 1750. The only difference is the value input for the storage_unit_ID parameter.

Invoking the lssu command
dscli>lssu -l 
The resulting output
Date/Time: Sun Aug 11 02:23:49 PST 2004 DS CLI Version: 5.0.0.0 
DS: IBM.1750-75FA120
Name ID Model WWNN

Pw
State

Pw
Mode

Desc
SU 1

IBM.2107-
75FA110

921

3007ACF
3012399
E0

On Local Test
SU 2

IBM.2107-
75FA120

921

3007ACF
3045699
E0

On Local

Produc-
tion

SU 3

IBM.2107-
75FA130

921

3007ACF
3078999
E0

On Local Backup

Report field definitions

Name
Specifies the user-defined name for each storage unit found within the storage complex. This value is null (-) if you have not assigned a name to a storage unit.
ID
Specifies the storage unit ID which consists of the manufacture name, machine type, and serial number. When the -s parameter is used, this is the only information that is displayed for the lssu command.
Model
Identifies the model number of the storage unit.
WWNN
Specifies the World Wide Node Name for the listed storage unit. This value is null (-) if the WWNN is not known
Pw State
Indicates the power status of the listed storage unit. One of the following values is displayed:
On
Indicates the storage unit power is on.
Off
Indicates the storage unit power is off.
Turning On
Indicates the storage unit power is in the process of turning on.
Turning Off
Indicates the storage unit power is in the process of turning off.
Power Exception
Indicates that storage unit power is on, but online operation is not possible due to a power fault in one of the storage unit frames.
Pw Mode
Indicates the power control mode in effect for the listed storage unit. One of the following values is displayed:
Local
Indicates that the SMC local/remote switch is set to the local power control mode.
Remote SMC Manual
Indicates that the SMC local/remote switch is set to remote and that the power control mode is set to manual power control.
Remote SMC Scheduled
Indicates that the SMC local/remote switch is set to remote and that the power control mode is set to scheduled power control.
Remote SMC Auto
Indicates that the SMC local/remote switch is set to remote and that the power control mode is set to auto-power control.
Remote SMC Scheduled/Auto
Indicates that the SMC local/remote switch is set to remote and that the power control mode is set to auto/scheduled power control.
Remote zSeries Power Control
Indicates that the SMC local/remote switch is set to remote and that the power control mode is set to zSeries remote power control.
Desc
Specifies the description that you assigned the storage unit. This value is displayed as a null (-) if no description has been assigned.
Related reference
chsu
showsu
Library | Support | Terms of use | Feedback