Configuring I/O ports

Complete this task to change the configuration for I/O ports that have host attachments assigned to them.

  1. In the navigation, select Real-time manager or Simulated manager > Manage hardware > Storage units. On the Storage units — Main Page, select a Storage unit.
  2. From the Select Action menu, select Configure I/O Ports..., and then click Go. The Configure I/O Ports page is displayed.
  3. Use the check boxes to select one or more host attachments of the same type.
  4. From the Select Action menu, select the I/O port type that you want to change to. You can change any I/O port to FcAl , FcSf , or FICON.
    FICON
    Select this if you plan to connect one or more S/390 hosts using a FICON S/390 channel to the DS6000 either directly or through a FICON switch.
    FcSf
    Select this if you plan to connect one or more open systems hosts to the DS6000 through a fabric switch, or if you plan to connect one or more S/390 hosts running LINUX on an FCP S/390 channel.
    FcAl
    Select this if you plan to connect an open systems host directly to the DS6000 without going through a fabric switch.
  5. Click Go. The table will update with the attachment type that you selected.

If you are setting up the DS Storage Manager, return to Setting up the DS Storage Manager and complete the rest of the steps.