Configure I/O Ports

Use this page to configure I/O ports that are connected to selected host attachments.

Introduction

You can change I/O ports to one of the following options: FcAl, FcSf, or FICON. Changes to the configuration of any I/O ports that already have host attachments that are assigned might prevent those hosts from accessing data using those ports.
Note: ESCON is not supported for the DS6000.

Menu path

Real-time manager or Simulated manager > Manage hardware > Storage units > Select a storage unit > Select Action: Configure I/O Ports... > Go

Fields

Select
The check boxes for the host attachments.
Interface Identifier
The interface identifier made up of four hex characters (0 - 9 or uppercase A - F). The value FFFF is reserved.
Type
The current interface for the I/O port:
FICON
Select this if you plan to connect one or more S/390 hosts using a FICON S/390 channel to the DS6000 either directly or through a FICON switch.
FcSf
Select this if you plan to connect one or more open systems hosts to the DS6000 through a fabric switch, or if you plan to connect one or more S/390 hosts running LINUX on an FCP S/390 channel.
FcAl
Select this if you plan to connect an open systems host directly to the DS6000 without going through a fabric switch.
Unknown
Select this if the type is unknown.
# of Host Attachments
The number of host attachments that are assigned to this storage unit port.
I/O Port Location
The location that provides the physical link. The value of the location code (R1-I3-C2-T1) is a combination of a rack, enclosure, processor card, and port, where the format is R[1 - 2]-I[1 - 8]-C[1 - 6]-T[0 - 3].
Related reference
DS6000 resource location codes
Library | Support | Terms of use | Feedback