Use this page to review a list of properties and basic capacity
calculations that represent new logical control units (LCUs).
Menu path
Fields
- Selected LCU(s)
- The quantity of LCUs that you have selected.
- SSID
- The subsystem identifier for the set of units that are attached to the
FICON host image.
- LCU type
- The supported count-key-data base control unit type (3990 Mod 3, 3990
Mod 3 for TPF, or 3990 Mod 6).
- Concurrent copy session timeout
- The time (in seconds) that a logical device on the LCU is allowed to remain
in a concurrent copy session with a "long busy" status. After the indicated
time, the concurrent copy session is suspended.
- z/OS Global Mirror Session timeout
- The time (in seconds) that any logical device on the LCU is allowed to
remain in an z/OS Global Mirror session with a "long busy" status. After the
indicated time, the z/OS Global Mirror session is suspended.
- Critical mode enabled
- Indicates whether the critical mode option is enabled for the LCU. Critical
mode controls the behavior of the remote mirror and copy pairs that have a
primary logical device on this logical subsystem (LSS) in an LSS consistency
group. If enabled, write operations to the source remote mirror and copy volume
are prohibited if data cannot be copied to the target volume of the volume
pair.