Complete this task to install or replace a disk drive module.
Attention: If you bring a disk drive module into the
operating environment from an area that is outside the normal operating temperature
of 20 - 25 degrees C (68 - 77 degrees F), allow the disk drive module time
to acclimate to the operating environment. Remove the disk drive module from
any shipping package, leave the disk drive module in the sealed plastic bag to prevent condensation from forming.
Important: When removing DDMs from an enclosure, care should be taken
to ensure that all resources from a particular server enclosure or expansion
enclosure are reinstalled into the same physical enclosure and in the same
location inside that enclosure.
If you are
installing additional storage, you must comply with the following rules:
- Update your license by submitting your Order Confirmation Code on the
DSFA Web site and by obtaining and entering your new license upgrade key in
the DS Storage Manager.
- Add DDMs in groups of four DDMs of the same capacity and speed.
- Add DDMs in a row, starting with the first DDM in the far left slot and
working your way across the enclosure so that the fourth DDM is in the far
right slot on the same row.
The disk drive modules are located in rows and columns
on the front of the storage unit.
If necessary, you can use the DS Storage Manager to verify that all DDMs are operational.
Note: You cannot leave
an empty disk drive module slot. You must insert either a replacement module
or a disk drive module blank to prevent overheating the storage unit.