Complete this task to modify the attributes and properties of established
logical control units (LCUs).
- In the navigation, select . On the LCUs main page, in the Select
storage unit drop-down list, select the storage unit that includes the LCU that you
want to modify.
- In the Select Action drop-down list, select Modify..., and then click Go.
The Modify LCU properties page is displayed.
- Define the parameters to modify the selected LCU.
- Select the LCU ID of the LCU that you want to modify.
- You can change the default SSID by highlighting and typing over
it.
- Specify the LCU types and establish the timeout times in seconds.
- Select a mode and, as necessary, establish the consistency group
timeout in seconds.
- Once you have modified the values, click OK to
complete the process and close the page.