Installing a QLogic adapter and driver for a Novell NetWare host

This section tells you how you install a QLogic adapter and driver on a Novell NetWare host system.

Single- and dual-port fibre-channel interfaces with the QLogic QLA23xx and QLA246x adapters support the following public and private loop modes:

Perform the following steps to install a QLogic adapter and driver:

Note: The following steps are an example of a configuration using the QLogic QLA23xx adapter. The configuration for your adapter might differ.
  1. Install the QLogic adapter in the host system.
  2. Connect the cable to the adapter and to the DS6000™ or switch port that you configured for the host adapter. If you have not configured host adapter ports on your DS6000, see Host configuration through the DS Storage Manager.
  3. Restart the server.
  4. Press Ctrl+Q to get to the FAST!Util menu.
  5. Use FAST!Util to set the parameters to the values listed in Table 1:
    Table 1. Recommended settings for the QLogic QLA23xx, and QLA246x adapters for a Novell NetWare host
    Parameters Recommended settings
    Basic Input/Output System (BIOS) Disabled
    Frame size 2048
    Loop reset delay 5 (minimum)
    Adapter hard loop ID Disabled
    Hard loop ID 0
    Execution throttle 16
    Fast command posting Enabled
    >4 GB addressing Disabled (for 32-bit systems)
    LUNs per target 32
    Note: Set LUNs per target to a number greater than the LUNs you have assigned to the adapter.
    Enable LIP reset No
    Enable LIP full login Yes
    Enable target reset Yes
    Login retry count 20 (minimum)
    Port down retry count 20 (minimum)
    Driver load RISC code Enabled
    Enable database updates No
    Disable database load No
    IOCB allocation 256
    Extended error logging Disabled (You might want to enable this parameter if you use debugging.)
    Type of connection
    • Loop only
    • Point-to-point
    • Loop preferred (If you cannot use arbitrated loop, then default to point-to-point.)
    • Point-to point, otherwise loop (If you cannot use point-to-point, default to arbitrated loop.)
    Note: If you connect the storage unit directly to the host system, the option you select must match the port connections on the storage unit.
  6. Install and configure the adapter driver on the host. See Installing a QLogic adapter driver for a Novell NetWare host for instructions.
  7. Restart the server.
Library | Support | Terms of use | Feedback