Resynchronizing a Metro Mirror volume pair

Use this process to resynchronize a volume pair in suspended mode.

When you resynchronize a Metro Mirror copy pair, all out-of-sync tracks on the source volume will be copied to the target volume.
  1. In the navigation, under Copy Services, select Metro Mirror. A page containing a list of Metro Mirror volumes displays. Select one or more volumes on which to perform an action.
  2. In the Metro Mirror — Main Page, select Resume from the Select Action drop-down box. Then, click Go.
  3. A confirmation box is displayed. Confirm the action to resynchronize the volume pair and allow operations to continue for the volume pairs.
Related tasks
Converting Global Copy volume pairs to synchronous
Library | Support | Terms of use | Feedback