Displaying zoning information for the switch

This section describes the command needed to display zoning information for the switch.

Use the cfgShow command to display the zoning information of the switch. Figure 1 shows a zoning example based on the unique worldwide port names of the host adapters and the storage unit fibre-channel ports. This is known as soft zoning. Each path to a storage unit LUN has a separate zone. For information on locating the worldwide port name for an SGI host, see "Locating the WWPN for an SGI host".

Figure 1. Example results for the cfgShow command
osvl2109c:admin> cfgShow
Defined configuration:
 cfg:   osvl_lab
                dc_1; w2k_1; MS6000Cluster; MSHPCluster; Tivoli; compaqzone1;
                compaqzone2; MS8500Cluster; AIX_ZONE; OSPL3Zone;
                MSCompaqCluster; SGI_Path1; SGI_Path2; NW;
                Netfyzone1; Netfyzone2; Netfyzone3; Netfyzone4 

 ...
 zone:  SGI_Path1
                SGI01; ospl3_b1a2
 zone:  SGI_Path2
                SGI02; ospl3_b4a2
 ...
 alias: SGI01   21:00:00:e0:8b:04:d5:39
 alias: SGI02   21:00:00:e0:8b:04:ee:3a
 alias: ospl3_b1a2
                50:05:07:63:00:c3:91:74

 alias: ospl3_b4a2
                50:05:07:63:00:c7:91:74

 ...

Effective configuration:
 cfg:   osvl_lab
 ... 
 zone:  SGI_Path1
                21:00:00:e0:8b:04:d5:39
                50:05:07:63:00:c3:91:74

 zone:  SGI_Path2
                21:00:00:e0:8b:04:ee:3a
                50:05:07:63:00:c7:91:74
 ...
Library | Support | Terms of use | Feedback
© Copyright IBM Corporation 2004, 2007. All Rights Reserved.