This section describes the command needed to display zoning information for the switch.
Use the cfgShow command to display the zoning information of the switch. Figure 1 shows a zoning example based on the unique worldwide port names of the host adapters and the storage unit fibre-channel ports. This is known as soft zoning. Each path to a storage unit LUN has a separate zone. For information on locating the worldwide port name for an SGI host, see "Locating the WWPN for an SGI host".
osvl2109c:admin> cfgShow
Defined configuration:
cfg: osvl_lab
dc_1; w2k_1; MS6000Cluster; MSHPCluster; Tivoli; compaqzone1;
compaqzone2; MS8500Cluster; AIX_ZONE; OSPL3Zone;
MSCompaqCluster; SGI_Path1; SGI_Path2; NW;
Netfyzone1; Netfyzone2; Netfyzone3; Netfyzone4
...
zone: SGI_Path1
SGI01; ospl3_b1a2
zone: SGI_Path2
SGI02; ospl3_b4a2
...
alias: SGI01 21:00:00:e0:8b:04:d5:39
alias: SGI02 21:00:00:e0:8b:04:ee:3a
alias: ospl3_b1a2
50:05:07:63:00:c3:91:74
alias: ospl3_b4a2
50:05:07:63:00:c7:91:74
...
Effective configuration:
cfg: osvl_lab
...
zone: SGI_Path1
21:00:00:e0:8b:04:d5:39
50:05:07:63:00:c3:91:74
zone: SGI_Path2
21:00:00:e0:8b:04:ee:3a
50:05:07:63:00:c7:91:74
...