This section describes how you install and configure an Emulex adapter card and driver for a Windows® 2000 or 2003 host.
Single- and dual-port, fibre-channel interfaces with an Emulex adapter card support the following public and private loop modes:
Complete the following steps to install and configure an Emulex adapter:
| Parameters - Exlcfg | Parameters - HBAnywhere | Recommended settings |
|---|---|---|
| Automatically map SCSI devices | Automap | Checked (enabled) |
| Query name server for all N-ports | NsQueryAll | Checked (enabled) |
| Allow multiple paths to SCSI targets | MultipleScsiClaims | Checked (enabled) |
| Register for state change | RegisterForStateChange | Checked (enabled) |
| Use report LUNs | UseReportLuns | Checked (enabled) |
| Use name server after RSCN | BrokenRscn | Checked (enabled) Obsolete for HBAnywhere (see note 1) |
| BusResetForBreakRes | - | (see note 2) |
| LUN mapping | MapLuns | Checked (enabled) |
| Automatic LUN mapping | MapLuns | Checked (enabled) |
| Scan in device ID order | ScanDeviceIdOrder | Not checked (disabled) |
| Disable target reset for tape devices | TapeResetMask | Not checked (disabled) |
| Use PLOGI instead of PDISC after LIP | ForcePlogi | Checked (enabled) |
| Enable class 2 for SCSI devices | Class2Enable | Not checked (disabled) |
| Report unknown SCSI devices | ShowUnknowns | Not checked (disabled) |
| Look for disappearing devices | AttemptReEstablish | Not checked (disabled) |
| Translate queue full to busy | TranslateQueueFull | Checked (enabled) if attached LUNs are part of a PPRC
or FlashCopy pair. Not checked (disabled) if attached LUNs are not part of a PPRC or FlashCopy pair. |
| Use bus reset status for retries | RegisterForStateChange | Not checked (disabled) |
| Retry unit attention | RetryUnitAttention | Not checked (disabled) |
| Retry PLOGI open failures | RetryPlogiOpenFailure | Not checked (disabled) |
| Enable FCP-2 Recovery | FcTape | Checked (enabled) |
| Enable FDMI | EnableFDMI | Not checked (disabled) |
| Maximum number of LUNs | MaximumLun | Equal to or greater than the number of the storage unit LUNs available to the host bus adapter |
| Maximum queue depth | MaximumQueueDepth | 8 |
| Driver Trace Mask 0x | ffTraceMask | 0 |
| Timer Settings (Tuning Drop Down Menu) | ||
| Link Timer | LinkDownTimer | 30 seconds (see note 3) |
| Retries | RetryAttempts | 64 (see note 3) |
| E_D_TOV | EDTOV | 2000 milliseconds (see note 3) |
| AL_TOV | EDTOV | 15 milliseconds (see note 3) |
| Wait ready timer | WaitReadyTimerVal | 45 seconds (see note 3) |
| Retry timer | RetryTimer | 2000 milliseconds (see note 3) |
| R_A_TOV | RATOV | 2 seconds (see note 3) |
| ARB_TOV | ARB_TOV | 1000 milliseconds (see note 3) |
| Tuning Link Control | ||
| Topology | InitLinkFlags |
|
| Link speed | InitLinkFlags | See above |
| Host pointers in SLIM | Unable to find corresponding value | Not checked (disabled) |
Notes:
|
||
Use Table 2 as a guideline for the recommended settings for the StorPort Miniport driver.
| Parameter | Recommended Settings |
|---|---|
| AutoMap | 2 (WWPN) |
| Class | 3 (Class 3 FC) |
| Coalesce MsCnt | 0 |
| CoalesceRspCnt | 8 |
| DiscoveryDelay | 0 |
| EnableAck0 | Enabled |
| EnableAck0 | 0 |
| FrameSizeMSB | 0 |
| HardAPIa | 0x0 |
| InitTimeOut | 15 |
| LinkSpeed | 4Gb or 2Gb |
| LinkTimeOut | 30 |
| LogErrors | 3 |
| NetworkOption | 0 |
| NodeTimeOut | 30 |
| NumFcpContext | 512 |
| QueueDepth | 32 |
| QueueTarget | 0 |
| RmaDepth | 16 |
| ScanDown | Enabled |
| TargetOption | 0 |
| Topology |
|
| TraceBufSiz | 250000 |
| UseAdisc | Disabled |