Removing the power supply

Complete this task to remove the power supply from an enclosure, either when the system is powered off or powered on.

DANGER
Electrical current safety warning
Hazardous voltage, current, or energy levels are present inside this resource.
3 minute power supply replacement warning
Attention: You must have a replacement resource unpacked and ready to insert into the expansion enclosure before you remove the existing power supply. The power supply must be replaced within three minutes to prevent possible loss of access to data. If you do not have a resource ready for immediate replacement, do not continue with these instructions.

Before you remove the power supply, the error indicator on the resource must be lit, unless the power supply is no longer receiving power.

Removing and replacing a power supply might result in the following effects:
  • Overheating has the potential to shut down the storage unit.
  • Access to data is lost if both power supplies are faulty or missing.
  • If the second power supply fails and the first power supply is not present in the enclosure, the enclosure loses power and you will lose access to all data.
  • If you are replacing the power supply in the server enclosure and the second power supply fails, the server enclosure and all attached expansion enclosures lose power and you will lose access to all data within those enclosures.
Important: When removing a power supply from an enclosure, care should be taken to ensure that all resources from a particular server enclosure or expansion enclosure are reinstalled into the same physical enclosure and in the same location inside that enclosure.

The power supplies are located on the right and left sides of the rear of the enclosure.

Location of power supplies

  1. Detach the power cable from the power supply.
  2. Press the release button. This releases the handle.
  3. Pull the handle out and towards the middle of the enclosure. This action partially ejects the power supply from the slot.
  4. Use the handle to pull the power supply partially out of the slot.
  5. Grip the power supply with both hands to pull the unit completely from the slot.
These images show a power supply removal procedure.
Power supply remove and replace procedure
You must immediately insert the replacement power supply into the server or expansion enclosure.