Before you remove a processor card, review the possible effects
that a processor card service action can have on your storage unit.
Removing and
replacing a processor card might result in the following effects:
Removing a processor card that does not have a solid amber error indicator
lit causes performance degradation and loss of access to data.
Note: Removing
a processor card that has a solid amber error indicator does not have any
effect on the operation of the storage unit.
If, while the first processor card is removed, the second processor card
fails, the enclosure will lose configuration settings and access to the data.
Data loss might occur if certain processes were occurring at the point of
failure.
Removing a processor card will cause loss of access to host systems if
multiple paths from the storage unit to the hosts are not configured.