Removing the disk drive module

Complete this task to remove the disk drive modules from the enclosure to reduce the weight of the enclosure during installation.

ESD warningUse approved ESD procedures to prevent damage.

The disk drive modules are located in rows and columns on the front of the storage unit.
Location of DDMs
Note: If you are removing a defective disk drive module to replace it, be sure to handle the defective disk drive module carefully. Damage to defective disk drive modules can have a negative effect on failure analysis and warranty recovery.

To remove a disk drive module, perform the following steps:

  1. Press the blue latch to release the disk drive module handle and pull the handle out and to your left. This action partially ejects the disk drive module out of its slot. Wait 30 seconds for the disk drive to spin down.
  2. Grip the disk drive module with both hands to pull it toward you and completely out of the slot. Ensure that the disk drive is properly aligned in a horizontal position until the drive is clear of the enclosure. Failure to do so can result in physical damage to the drive or the drive component.
These images show a disk drive module removal procedure.
DDM remove and replace procedure
Important: All disk drive module slots must be filled to prevent overheating the storage unit. If necessary, insert a disk drive module blank in the empty slot.
Library | Support | Terms of use | Feedback