CMUN80026E REFERENCE The DS Network Interface server is aware of the storage unit, but unable to communicate with it.

Explanation

The DS Network Interface server is unable to communicate with the storage unit. The storage unit was previously available, but might now be offline.

Action

Perform the following actions to correct the problem:
  • Check that all cables are connected appropriately between the management console and the server enclosure or from the expansion enclosures to the server enclosure. If cables are not connected appropriately, correct the connection and resubmit the task.
  • Check that the server enclosure is not currently initializing. If the server is initializing, wait for initialization to complete, and then resubmit the task.
  • Check that the server enclosure is online and not powered off as a result of a shutdown, restart, warm start. If the server enclosure is powered off, power on the server enclosure and resubmit the task.
  • Check that a code load is not in process. If code is currently being loaded onto the enclosure, wait for it to complete and resubmit the task.
If the problem persists, contact IBM technical support for assistance.