The Early Release Patch (ERP) kits delivered in this Engineering Advisory (EA) 
correct the following issues identified on the HP Tru64 UNIX operating system.

1) Potential KMF in tape cam_changer code   
                   
A potential KMF can occur in the cam_changer code if more than one thread 
attempts to access the changer at the same time. For example, if a robot is 
moving tapes and another thread opens the same device the panic event is likely 
to occur.  This panic is more likely occur if the customer is running tape 
backup software that uses multiple changer threads.

2) Potential Dead Lock issue in tape cam_changer code.

A potential Dead Lock can occur in cam_changer code while accessing media 
changer. This event will likely to occur when the previous changer 
application failed with an error SCSI device busy