			 Release Notes

     This document summarizes the contents and special instructions for the 
     TruCluster Server V5.1 patches contained in this kit.


1 Release Notes


This Customer-Specific Patch Kit Distribution contains: 

   - fixes which are intended to resolve the problem(s) reported in: 
        o GB_G01736 
             * for TruCluster Server V5.1 T64V51AS0003-20010413.tar (BL17)

 WARNING! NOT FOR GENERAL USE.
          These patches are tailored for an individual system's hardware and
          software configuration. Use of this patch kit, or patches contained
          in this kit, on any other system may cause that system to be in an
          inconsistent and non-operational state.

          This patch kit, or its content, may not be posted on any network or
          bulletin boards.


 The Release Notes contain a summary of each patch in this kit.

 Patches in this kit are installed by manually typing commands or by the 
 simple installation script included in the kit. For example, as root on 
 the target system:

        > mkdir -p /tmp/CSPkit1
        > cd /tmp/CSPkit1
        > <copy the kit to /tmp/CSPkit1>
        > tar -xpvf DUV40D13-C0045600-1340-Manual-20000404.tar 
	> cd patch_kit/DIGITAL_UNIX_V4.0D/ManualKit
	> ./OSFPATC0045600425.install.sh

 NOTE: The simple installation script provides:

	o Prior to installing anything, it verifies 
		- product version matches the target product for the patch
		- affected product subsets are installed

	o Saves existing system files (so the patch can be removed)
		- in their current location with .PreManualCSP.<timestamp> 
		  appended	

	o Installs patched system files in the proper location with the proper 
	  access modes

	o Installs the patch documentation on the target system
		- copies <PatchID>.abs, 
		  	 <PatchID>.txt, 
			 <PatchID>.problem_ids, 
		  	 <PatchID>.rcs_strings and optionally 
		  	 <PatchID>.special_instructions

		  to /var/adm/manual_patch/doc

	o Updates the manually-installed patch installation log 
		- /var/adm/manual_patch/log/Install.log

	o Updates the manually-installed patch database
		- copies <ManualPatchName>.sh
			 <ManualPatchName>.FileList
			 <ManualPatchName>.Installed

		  to /var/adm/manual_patch/db/

	The installation script DOES not provide patch dependency management 
	nor patch removal capabilities.

 These patches have been tested and found to work correctly in the support
 engineering environment. However, it is possible that you may experience 
 different results running these patches in your computing environment.

 Compaq recommends that you install these patches in a NON-Production (testing)
 computing environment to ensure there are no side-effects (due to your specific
 configurations) PRIOR to installing the patches in your production environment.

 
2 Special Instructions

There are no special instructions for TruCluster Server V5.1 Patch C122.02


3 Summary of CSPatches contained in this kit


TruCluster Server V5.1

PatchId			Summary Of Fix
----------------------------------------
C122.02			Network superpatch


4 Additional information from Engineering


None

5 Affected system files
This patch delivers the following files:

TruCluster Server V5.1
	Patch C122.02
		./usr/opt/TruCluster/sys/clua.mod
			CHECKSUM:	62810 492
			SUBSET:	TCRBASE510