|
|
 |

SSRT2208 - HP Tru64 UNIX /usr/sbin/routed Potential Security Vulnerability
|
TITLE: SSRT2208 - HP Tru64 UNIX /usr/sbin/routed Potential Security Vulnerability
New Kit Date: 10-OCT-2002
Modification Date: Not Applicable
Modification Type: NEW KIT
Copyright (c) Hewlett-Packard Company 2002. All rights reserved.
PRODUCT: Tru64 UNIX [R] 5.1
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: T64V51B19-C0140503-15377-ES-20020906
ECO Kit Approximate Size: 1.6MB
Kit Applies To: Tru64 UNIX 5.1 PK5 (BL19)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
30182 1540
/usr/bin/cksum results:
1144654403 1576960
MD5 results:
7d51b5ffab9458b661141f8b29447215
SHA1 results:
ee5f7e1f28b14c0be63d3295fea5d6a00db6332e
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for Tru64 UNIX 5.1 that
contains solutions to the following problem(s):
A potential security vulnerability has been discovered in the HP Tru64 UNIX
operating system that may result in unauthorized access to files on the
system. This potential vulnerability may be in the form of local and remote
security domain risks.
The following potential security vulnerability has been corrected:
o SSRT2208 /usr/sbin/routed (Severity - High)
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
The patches in this ERP kit will also be available in the next mainstream
patch kit - Tru64 UNIX 5.1 Patch Kit 7.
INSTALLATION NOTES:
1) Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
2) The patch in this ERP kit does not have any file intersections with any
other ERP available at this time for this product version.
3) This ERP kit will NOT install over any Customer-Specific-Patches (CSPs)
which have file intersections with this ERP kit. Contact your normal
Service Provider for assistance if the installation of this ERP kit is
blocked by any of your installed CSPs.
INSTALLATION PREREQUISITES:
You must have installed Tru64 UNIX 5.1 PK5 (BL19) prior to installing
this Early Release Patch Kit.
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR T64V51B19-C0140503-15377-ES-20020906:
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o 117-2-709 SSRT2208
* for Tru64 UNIX V5.1 T64V51B19AS0005-20020411.tar (BL19)
The patches in this kit are being released early for general customer use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
There are no special instructions for Tru64 UNIX V5.1 Patch C1405.03
3 Summary of CSPatches contained in this kit
Tru64 UNIX V5.1
PatchId Summary Of Fix
----------------------------------------
C1405.03 Fix for SSRT2208, routed
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
Tru64 UNIX V5.1
Patch C1405.03
./usr/lib/nls/msg/en_US.ISO8859-1/routed.cat
CHECKSUM: 51932 2
SUBSET: OSFCLINET510
./usr/sbin/routed
CHECKSUM: 07941 65
SUBSET: OSFCLINET510
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2002. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection
and back-up data used in conjunction with this ECO/workaround.
Files on this server are as follows:
|
»t64v51b19-c0140503-15377-es-20020906.README
»t64v51b19-c0140503-15377-es-20020906.CHKSUM
»t64v51b19-c0140503-15377-es-20020906.tar
|