Tru64 UNIX fixfdmn should not be used to repair Advfs domains
|
TITLE: Tru64 UNIX fixfdmn should not be used to repair Advfs domains
which use property lists
New Kit Date: 14-JAN-2003
Modification Date: Not Applicable
Modification Type: NEW KIT
Copyright (c) Hewlett-Packard Company 2002. All rights reserved.
PRODUCT: HP Tru64 UNIX [R] 5.1
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: T64V51B19-C0164601-16326-E-20021206
ECO Kit Approximate Size: 2 MB
Kit Applies To: HP Tru64 UNIX V5.1 PK5 (BL19)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
14192 1960
/usr/bin/cksum results:
1443765650 2007040
MD5 results:
84c06fa47fa0f962af82ae268a08a5db
SHA1 results:
79203fbfca4ba3e67db3bebc2fa74c0dceb2fe50
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for HP Tru64 UNIX V5.1 that
contains solutions to the following problem(s):
HP Tru64 Engineering determined that fixfdmn may cause AdvFS domains
to be improperly repaired. This problem was reported on domains that
have property lists (ACLs or Access Control Lists) defined. When ACLs
are defined, fixfdmn incorrectly interprets that the property lists
are improper and removes the AdvFS mcells (metadata) associated with
these property lists. HP Tru64 Engineering has corrected this problem.
[ Note: To determine whether or not ACL are enabled, refer to the
reference page for getacl. ]
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
The patches in this ERP kit will also be available in
HP Tru64 UNIX V5.1 Patch Kit 7
INSTALLATION NOTES:
Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
INSTALLATION PREREQUISITES:
You must have installed HP Tru64 UNIX V5.1 PK5 (BL19) prior to installing
this Early Release Patch Kit.
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR T64V51B19-C0164601-16326-E-20021206:
Release Notes
This document summarizes the contents and special instructions for
the Tru64 UNIX V5.1 patches contained in this kit.
For information about installing or removing patches, baselining,
and general patch management, see the Patch Kit Installation
Instructions document.
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o DSATM1GT8 TSTQM0ZX6
* for Tru64 UNIX V5.1 T64V51B19AS0005-20020411.tar (BL19)
The patches in this kit are being released early for general customer
use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target
system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
There are no special instructions for Tru64 UNIX V5.1 Patch C1646.01
3 Summary of CSPatches contained in this kit
Tru64 UNIX V5.1
PatchId Summary Of Fix
----------------------------------------
C1646.01 Corrections to fixfdmn program
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
Tru64 UNIX V5.1
Patch C1646.01
./sbin/advfs/fixfdmn
CHECKSUM: 23843 387
SUBSET: OSFADVFS510
./usr/lib/nls/msg/en_US.ISO8859-1/fixfdmn.cat
CHECKSUM: 52128 48
SUBSET: OSFADVFS510
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2002. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection
and back-up data used in conjunction with this ECO/workaround.
Files on this server are as follows:
|
»t64v51b19-c0164601-16326-e-20021206.README
»t64v51b19-c0164601-16326-e-20021206.CHKSUM
»t64v51b19-c0164601-16326-e-20021206.tar
|