HP TruCluster Server Cluster Interconnect Potential Security Vulnerability
|
TITLE: HP TruCluster Server Cluster Interconnect Potential Security Vulnerability
TITLE: HP TruCluster Server Cluster Interconnect Potential Security Vulnerability
Copyright (c) Hewlett-Packard Company 2002. All rights reserved.
PRODUCT: TruCluster Server [R] 5.1
SOURCE: Hewlett-Packard Company
ECO INFORMATION:
ECO Name: TCV51B19-C0030403-15347-ES-20020905
ECO Kit Approximate Size: 1.6MB
Kit Applies To: TruCluster Server 5.1 PK5 (BL19)
ECO Kit CHECKSUMS:
/usr/bin/sum results:
04763 1560
/usr/bin/cksum results:
3173171465 1597440
MD5 results:
bbea37ded54ee939527f79363a402083
SHA1 results:
49ad498b3023c6db54f7f1c3c8e3d9c9af27a385
ECO KIT SUMMARY:
A dupatch-based, Early Release Patch kit exists for TruCluster Server 5.1 that
contains solutions to the following problem(s):
A potential security vulnerability has been discovered in HP TruCluster Server
software that may result in a denial of service (DoS). This potential
vulnerability may be in the form of local and remote security domain risks.
The following potential security vulnerability has been corrected:
o SSRT2265 Cluster Interconnect (Severity - High)
Cross Reference: CAN-2002-0711
The Patch Kit Installation Instructions and the Patch Summary and Release
Notes documents provide patch kit installation and removal instructions
and a summary of each patch. Please read these documents prior to
installing patches on your system.
The patches in this ERP kit will also be available in TruCluster Server 5.1
Patch Kit 7.
INSTALLATION NOTES:
1) Install this kit with the dupatch utility that is included in the patch
kit. You may need to baseline your system if you have manually changed
system files on your system. The dupatch utility provides the baselining
capability.
2) This ERP kit will NOT install over any installed Customer Specific Patches
(CSPs) which have file intersections with this ERP kit. Contact your normal
Service Provider for assistance if the installation of this ERP kit is
blocked by any of your installed CSPs.
3) The ERP kits DO NOT have any file intersections with any other
available ERPs for this product version.
INSTALLATION PREREQUISITES:
You must have installed TruCluster Server 5.1 PK5 (BL19) prior to installing
this Early Release Patch Kit.
KNOWN PROBLEMS WITH THE PATCH KIT:
None.
RELEASE NOTES FOR TCV51B19-C0030403-15347-ES-20020905:
1 Release Notes
This Early Release Patch Kit Distribution contains:
- fixes that resolve the problem(s) reported in:
o SSRT2265
* for TruCluster Server V5.1 T64V51B19AS0005-20020411.tar (BL19)
The patches in this kit are being released early for general customer use.
Refer to the Release Notes for a summary of each patch and installation
prerequisites.
Patches in this kit are installed by running dupatch from the directory
in which the kit was untarred. For example, as root on the target system:
> mkdir -p /tmp/CSPkit1
> cd /tmp/CSPkit1
>
> tar -xpvf DUV40D13-C0044900-1285-20000328.tar
> cd patch_kit
> ./dupatch
2 Special Instructions
There are no special instructions for TruCluster Server V5.1 Patch C304.03
3 Summary of CSPatches contained in this kit
TruCluster Server V5.1
PatchId Summary Of Fix
----------------------------------------
C304.03 Fix for SSRT2265, cluster interconnect
4 Additional information from Engineering
None
5 Affected system files
This patch delivers the following files:
TruCluster Server V5.1
Patch C304.03
./usr/lib/nls/msg/en_US.ISO8859-1/clu_upgrade.cat
CHECKSUM: 30557 20
SUBSET: TCRBASE510
./usr/sbin/clu_upgrade
CHECKSUM: 18851 78
SUBSET: TCRBASE510
./usr/sbin/cluster/clu_ifaccess
CHECKSUM: 65518 6
SUBSET: TCRUnknown
[R] UNIX is a registered trademark in the United States and other countries
licensed exclusively through X/Open Company Limited.
Copyright Hewlett-Packard Company 2002. All Rights reserved.
This software is proprietary to and embodies the confidential technology
of Hewlett-Packard Company. Possession, use, or copying of this
software and media is authorized only pursuant to a valid written license
from Hewlett-Packard or an authorized sublicensor.
This ECO has not been through an exhaustive field test process.
Due to the experimental stage of this ECO/workaround, Hewlett-Packard
makes no representations regarding its use or performance. The
customer shall have the sole responsibility for adequate protection
and back-up data used in conjunction with this ECO/workaround.
Files on this server are as follows:
|
»tcv51b19-c0030403-15347-es-20020905.README
»tcv51b19-c0030403-15347-es-20020905.CHKSUM
»tcv51b19-c0030403-15347-es-20020905.tar
|