FIX: Redirecting Output to an MS-DOS Application
PSS ID Number: Q105303
Article last modified on 07-27-1994

3.10

WINDOWS NT


----------------------------------------------------------------------
The information in this article applies to:

 - Microsoft Win32 Software Development Kit (SDK) for Windows NT
   version 3.1
----------------------------------------------------------------------

SYMPTOMS
========

The following method is used to redirect output to a child process when it
is started from a GUI application:

1. Declare STARTUPINFO si.

   a. Set the hStdIn, hStdOut, and/or hStdErr field as desired.
   b. Set the dwFlags field to STARTF_USESTDHANDLES.

2. In CreateProcess(), set inherit handles to TRUE.

NOTE: This method does not work when starting MS-DOS applications.

RESOLUTION
==========

As a workaround, use AllocConsole(), then the following method:

1. Use SetStdHandle() to set the desired handles to be inherited.

   -or-

   Use DuplicateHandle() to change the inheritance property of handles
   that should not be inherited.

3. In CreateProcess(), set inherit handles to TRUE.

This method creates a blank console window; however, this is necessary
because the method doesn't work otherwise.

STATUS
======

Microsoft has confirmed this to be a bug in Windows NT 3.1. This problem
was corrected in Windows NT 3.5.

MORE INFORMATION
================

Note that if you are opening a handle that will be inherited by the
child, set SECURITY_ATTRIBUTES.bInheritHandle = TRUE in the call to
CreateFile(), CreatePipe(), and so forth.

For an example of both methods of redirection, see the INHERIT SDK
sample.

Additional reference words: 3.10
KBCategory: Prg
KBSubcategory: BseProcThrd

=============================================================================

Copyright Microsoft Corporation 1994.