Patch3 RECEIVE_ALLOC on APPC Service TP Name Doesn't Attach
  
PSS ID Number: Q107219
Article last modified on 04-23-1996
 
2.00
 
WINDOWS
 

---------------------------------------------------------------------------
The information in this article applies to:
 
 - Microsoft SNA Server for Windows NT, version 2.0
---------------------------------------------------------------------------
 
SYMPTOMS
========
 
If APPC-invokable transaction programs (TPs) are being used with SNA
Server and the first character of a TP name is less than EBCDIC hex
0x40, the incoming allocate fails.
 
RESOLUTION
==========
 
The SYSTEM\SNADMOD.DLL module has been updated and is available on
Library 1 of the MSSNA forum on CompuServe.
 
To install the updated module on the Windows NT machine where the
invokable APPC TP is to run, do the following:
 
1. From a command prompt, type the following and press ENTER:
 
      NET STOP SNABASE
 
   This stops all SNA Server processes on the machine (and forces off
   all current SNA Server users if entered at the server).
 
2. Copy the patched module to the <SNARoot>\SYSTEM directory.
 
3. Restart the computer by typing the following and pressing ENTER:
 
      NET START SNABASE
 
Additional reference words: prodsna 2.00 APPC
KBCategory: kbnetwork
KBSubcategory: ntgeneral
=============================================================================
Copyright Microsoft Corporation 1996.