HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\UPS BatteryLife REG_DWORD 2 to 720 minutes ------------------------------------------ Default: 2 (minutes)Specifies the life of the UPS backup battery when fully charged.
CommandFile REG_EXPAND_SZ Filename -------------------------------------- Default: (empty)Specifies the name of a command file to execute immediately before shutting down.
FirstMessageDelay REG_DWORD 0 to 120 seconds ------------------------------------------------ Default: 5 (seconds)Specifies the number of seconds between initial power failure and the first message sent to the users. If power is restored within the FirstMessageDelay time, no message is sent, although the event is logged.
MessageInterval REG_DWORD 5 to 300 seconds ---------------------------------------------- Default: 120 (seconds)Specifies the number of seconds between messages sent to users to inform them of power failure.
Options REG_DWORD Value ---------------------------Defines the bit mask for messages related to options in the UPS dialog box, as the following:
Installed 0x00000001 PowerFailSignal 0x00000002 LowBatterySignal 0x00000004 CanTurnOff 0x00000008 PosSigOnPowerFail 0x00000010 PosSigOnLowBattery 0x00000020 PosSigShutOff 0x00000040 CommandFile 0x00000080 Port REG_SZ Port name ------------------------- Default: COM1Specifies the name of the serial port the UPS is connected to.
RechargeRate REG_DWORD 1 to 250 minutes ------------------------------------------- Default: 100 (minutes)Specifies the recharge rate of the UPS backup battery.