Article ID: 106275
Article Last Modified on 1/8/2000
A: This could mean Setup had difficulty recognizing your hardware, or there is a conflict with a TSR or device driver loading in the CONFIG.SYS or AUTOEXEC.BAT. You first need to exit Setup by pressing the F3 key. If this does not exit Setup, restart the machine. See the section "Streamlining Your CONFIG.SYS and AUTOEXEC.BAT Files," in Appendix E, "Troubleshooting," in the Microsoft Workgroup Add-On for Windows User's Guide, for more information on creating a minimal CONFIG.SYS and AUTOEXEC.BAT. You will then need to run Setup again and install Windows for Workgroups 3.11 into the same directory. Setup will automatically turn off some of its hardware detection capability to try to prevent a hardware detection problem from occurring again. If you still encounter problems during Setup, restart your computer and type the following at the MS-DOS command prompt:
SETUP /I
A: If you have completed Setup but cannot start Windows for Workgroups 3.11, see the section "Windows won't start after a successful Setup," in Appendix E "Troubleshooting," in the Microsoft Workgroup Add-On for Windows User's Guide. This section list the most common causes of not being able to start Windows for Workgroups 3.11, and how to correct these problems.
A: Windows for Workgroups 3.11 can use the ODI drivers to communicate with both Novell Netware servers and other computers using Windows for Workgroups 3.11. Before setting up Windows for Workgroups 3.11, you must have the ODI drivers loaded and configured properly for your network adapter. You will also need to obtain support drivers that Novell provides for Netware functionality within Windows operating systems. Contact you local Novell reseller or Novell's CompuServe forums for information on obtaining these drivers. When installing support for Netware connectivity using the ODI drivers, Setup will prompt you for these files. If you are upgrading over Windows for Workgroups 3.1 or Windows 3.1, and had Netware connectivity enabled, these support drivers will already exist in your Windows directory. Setup will detect these files and will prompt you to choose to use these files, or install the diskette from Novell. For more information on configuring Windows for Workgroups 3.11 with the ODI drivers, please refer to the NETWORKS.WRI file, located in your Windows for Workgroups 3.11 directory. This file can be viewed with the Write application in Windows for Workgroups 3.11
A: 32-BIT FILE ACCESS provides a faster way to read and write to the
disk cache in Windows for Workgroups 3.11 than SMARTDrive can provide.
It provides a much higher disk access performance boost on compatible
hard drive controllers when running Windows for Workgroups 3.11 by
utilizing a 32-bit cache as opposed to SMARTDrive's 16-bit cache.
However, SMARTDrive is still used for caching floppy drives with
Windows for Workgroups 3.11.
By default, 32-BIT FILE ACCESS is NOT enabled. For more information on
activating this disk performance enhancement utility, see the section
"Improving Performance," Chapter 8 of the Microsoft Workgroup Add-On
for Windows User's Guide.
A: PLEASE NOTE: These files should only be used if Windows for
Workgroups 3.11 worked properly after its initial install.
The files listed above are created by Setup after it installs Windows
for Workgroups 3.11 onto your harddrive. They are to be used if, for
some reason, Windows for Workgroups 3.11 cannot start, or is not
functioning properly after a change was made to one of three files:
PROTOCOL.INI, SYSTEM.INI, and WIN.INI. To restore these files to
their original settings, you need to first make a backup copy onto a
floppy diskette of your PROTOCOL.INI, SYSTEM.INI, and WIN.INI files
from your directory. Next, copy the PROTOCOL.CLN, SYSTEM.CLN, and
WIN.CLN files in your Windows for Workgroups 3.11 directory to
PROTOCOL.INI, SYSTEM.INI, and WIN.INI respectively. This will
restore your files to their original settings.
A: Yes. If you had a previous version of Windows 3.1 or Windows for Workgroups 3.1, and had one of these video drivers installed, Setup will recognized this and will keep this driver for use in Windows for Workgroups 3.11.
A: Yes. You will need to purchase the Microsoft Workgroup Add-On for MS-DOS package from Microsoft, and install a compatible network adapter on the computer. This product allows you to connect to Windows for Workgroups 3.11 computers and printers, and also allows you to share your files with other computers on the network from MS-DOS. For more information about this product, please call Microsoft Sales Information Center (MSIC) at (800) 426-9400.
A: In the previous version, Windows for Workgroups 3.1, a Windows for Workgroups computer communicated with other Windows for Workgroups computers using the NetBEUI protocol by default. With Windows for Workgroups 3.11, a second protocol, either IPX/SPX Compatible Transport or IPX/SPX Compatible Transport with NETBIOS, is installed along with NetBEUI, if the computer has six megabytes or more of RAM. This allows Windows for Workgroups 3.11 to communicate with other computers that use either the NetBEUI protocol or IPX/SPX Compatible Transport. The benefit of the IPX/SPX Compatible Transport and the IPX/SPX Compatible Transport with NETBIOS is that either of these protocols can communicate across a router, whereas the NetBEUI protocol cannot. Novell Netware servers can act as routers between two different Windows for Workgroups 3.11 networks.
Additional query words: 3.11 Q&A
Keywords: KB106275