FIX: Typing 80 Characters in a Watch Window Can Hang the VWB
PSS ID Number: 106637
Article Last Modified on 3/24/2000
The information in this article applies to:
- Microsoft FORTRAN PowerStation for MS-DOS 1.0
This article was previously published under Q106637
SYMPTOMS
Typing a string of 80 or more characters in the Watch window and
pressing the ENTER key hangs the Visual Workbench (VWB) if the string
of characters does not contain spaces or FORTRAN operators.
RESOLUTION
Avoid entering large blocks of non-FORTRAN text into the Watch window.
This problem is typically caused by pasting from the clipboard, so do
not paste into the Watch without being certain that the text in the
clipboard is a FORTRAN expression.
STATUS
Microsoft has confirmed this to be a problem in FORTRAN PowerStation
version 1.0 for MS-DOS. This problem has been resolved with FORTRAN
PowerStation maintenance release version 1.0a for MS-DOS.
Additional query words: 1.00 buglist1.00 fixlist1.00a
Keywords: kbbug KB106637