Knowledge Base

Sytos Fails Adding Volumes with Enhanced-mode 1742 Controller

Article ID: 114945

Article Last Modified on 10/31/2006

This article was previously published under Q114945

SYMPTOMS

When the Adaptec 1742 tape controller is running in enhanced mode, Sytos may perform tape backup correctly but trap when trying to add a volume back from tape. If you attempt to view a catalog, you may also have to wait hours to obtain it.

CAUSE

These problems are related to configuring the Adaptec 1742 controller in enhanced mode, and running older versions of Sytos software.

RESOLUTION

  1. Upgrade the Sytos software to the newest version. (Currently 1.38)
  2. Configure the Adaptec 1742 controller to run in Standard mode, thereby forcing it to use the AHA154x.BID file as the device driver.
  3. Use a known good version of the AHA154x.BID file (AHA154x.BID dated 11/15/91).

Additional query words: 2.20 2.2