OS/2 IOPL Applications May Fail in Windows NT
Article ID: 120055
Article Last Modified on 10/31/2006
APPLIES TO
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
- Microsoft Windows NT Advanced Server 3.1
This article was previously published under Q120055
3.10
WINDOWS
kb3rdparty kbbug3.10
SYMPTOMS
An OS/2 application with Ring2 code (an IOPL application) running in
Windows NT may hang with the error message:
Error OS/2 error code 8
Note: This is an OS/2 message. Other OS/2 applications may fail to run
after a number of Ring2 applications are loaded.
CAUSE
By design, an OS/2 application with Ring2 code and no IN/OUT instructions
cannot run on Windows NT. After you run about 90 such applications, no
additional OS/2 applications can be run until you stop and restart OS2SRV
or reboot your computer.
STATUS
Microsoft has confirmed this to be a problem in Windows NT and Windows NT
Advanced Server version 3.1. This problem has been corrected in Windows NT
Workstation and Windows NT Server version 3.5.
Additional query words: prodnt 3.10
Keywords: KB120055