Problems Copying Large Files Using Texel DM 3024 CD-ROM
Article ID: 123439
Article Last Modified on 11/15/2006
APPLIES TO
This article was previously published under Q123439
SYMPTOMS
When you use the Texel DM 3024 CD-ROM drive on a system running in a
multi-threaded environment, such as Windows 95, Windows NT, OS/2, Novell
NetWare, or Unix, one of the following problems occurs:
- Data corruption during large file (over 1.5 megabytes) copy operations.
-or-
- Disk errors, such as "Cannot write to Drive C:"
CAUSE
The Texel DM 3024 CD-ROM drive requires firmware version 1.10 or later to
function properly in a multi-threaded environment.
RESOLUTION
It may be possible to determine the CD-ROM drive's firmware version by
running the diagnostics utilities provided with most SCSI adapters. If no
diagnostics utilities are available, contact Plextor (formerly Texel) for
information about how to determine whether or not the CD-ROM drive needs to
be updated.
The most recent version of the firmware for this CD-ROM drive is 1.13.
Additional query words: 3rdparty err msg
Keywords: KB123439