Problems Running SNA Server 5250 Applet (Autoconnect Enabled)
Article ID: 126546
Article Last Modified on 10/23/2003
APPLIES TO
- Microsoft SNA Server 2.1, when used with:
This article was previously published under Q126546
SYMPTOMS
If you run the SNA Server 2.1 5250 applet, and the 5250 Session/Autoconnect
switch is enabled, the following problems can occur:
CAUSE
The SNA Server 5250 applet does not wait long enough for the underlying SNA
client module (WNAP) to initialize, and then fails to work properly when
WNAP fails to initialize.
RESOLUTION
To workaround this problem in SNA Server version 2.1, configure WNAP to
start before the 5250 applet is started. To do this, add a WNAP.EXE icon to
the Windows or Windows for Workgroups Startup group.
STATUS
Microsoft has confirmed this to be a problem in SNA Server version 2.1.
This problem was corrected in SNA Server version 2.11.