NetFlex-II NIC Does Not Bind When Digiboard PCIMAC Installed
Article ID: 128801
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Advanced Server 3.1
- Microsoft Windows NT Workstation 3.1
This article was previously published under Q128801
SYMPTOMS
After you install a Digiboard PCIMAC on a Compaq Prosignia VS computer
with a built-in Netflex-II network interface card (NIC), the following is
logged in the Event Viewer:
Event ID: 7000
Source: Service Control Manager
Type: Error
Description: The Compaq integrated Netflex-II ENET driver service
failed to start due to the following error: A device attached to the
system is not functioning.
Event ID: 9006
Source: Nbf
Type: Error
Description: Nbf could not find adapter \Device\pcntn311.
Event ID: 9005
Source: Nbf
Type: Error
Description: Nbf failed to bind to adapter \Device\pcntn311.
Event ID: 2504
Source: Server
Type: Error
Description: The server could not bind to the transport
\Device\Nbf_pcntn311.
WORKAROUND
To work around this problem, disable the built-in NetFlex-II NIC and
install another supported NIC.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.1.
We are researching this problem and will post new information here in
the Microsoft Knowledge Base as it becomes available.
Additional query words: prodnt 3.10
Keywords: KB128801