Knowledge Base

PRB: GP Fault When Using 16-Bit Automation DLLs

Article ID: 131047

Article Last Modified on 12/8/1999


APPLIES TO


This article was previously published under Q131047

SYMPTOMS

After dynamically loading and then unloading one of the 16-bit OLE Automation DLLs (OLE2DISP.DLL, LOE2NLS.DLL, or TYPELIB.DLL), you experience a general protection (GP) fault in COMPOBJ.DLL.

CAUSE

If any of the 16-bit OLE Automation DLLs (OLE2DISP.DLL, LOE2NLS.DLL, or TYPELIB.DLL) is dynamically loaded, it should not be unloaded until after OleUninitialize has been called. Otherwise a general protection (GP) fault can occur in COMPOBJ.DLL.

RESOLUTION

If you dynamically load any of the 16-bit OLE Automation DLLs (OLE2DISP.DLL, LOE2NLS.DLL, or TYPELIB.DLL), don't unload it until OleUninitialize has been called.

STATUS

This requirement is by design.