PC DirSync: Err Msg: Fatal 39 Error Generating TID
Article ID: 135486
Article Last Modified on 10/30/2006
APPLIES TO
- Microsoft Mail for PC Networks 3.2
- Microsoft Mail for PC Networks 3.2a
- Microsoft Mail for PC Networks 3.5
This article was previously published under Q135486
SYMPTOMS
When REBUILD.EXE is run to build the Global Address List (GAL), the
following error may be displayed in the DIRSYNC.LOG:
Fatal 39 Error generating TID. Allocating unique ID.
CAUSE
This error occurs if the GALNETPO.GLB on the postoffice is corrupt.
RESOLUTION
To correct this, delete GAL.NME, GALINDEX.GLB, and GALNETPO.GLB. Re-run
REBUILD.EXE to recreate the files.
MORE INFORMATION
When Rebuild constructs the GALNETPO.GLB, it starts out with an arbitrarily
large number, 7F67697F (in hex) as default, for the new tuple identifier
(TID). Then it reads the GALNETPO.GLB; it reads the first 4 bytes and the
first record to determine the new TID value in GALNETPO.GLB. If this is
successful, it uses this number instead of the default for the new TID
value.
Then the TID.GLB is read. The value from this is compared with the new TID
obtained previously. If the new TID is less than or equal to the value from
TID.GLB, the error 39 is generated. The new TID is expected to be
arbitrarily large.
If the GALNETPO.GLB is corrupt and consists of records containing all
zeroes, this error will occur. If you delete the GAL files, the default new
TID will be used.
Additional query words: 3.20 3.20a 3.50