Unable to Read Error 52225 During Windows NT Setup
Article ID: 137064
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT Workstation 3.5
- Microsoft Windows NT Workstation 3.51
- Microsoft Windows NT Workstation 4.0 Developer Edition
- Microsoft Windows NT Server 3.5
- Microsoft Windows NT Server 3.51
- Microsoft Windows NT Server 4.0 Standard Edition
This article was previously published under Q137064
SYMPTOMS
When you install Windows NT Server or Workstation, the following error
appears during the text mode portion of Setup:
UNABLE TO READ
Error 52225 line 1933
D:\winnt\private\ntos\boot\setup\setup.c
-or-
ERROR
Unexpected error [769] occured at
Line 1933 in d:\nt\private\ntos\boot\setup.c
Press any key to continue
-or -
The error during Windows NT V4.0 setup is as follows:
Unexpected error (256) occurred at
Line 2180 in d:\nt\private\ntos\boot\setup\setup.c
Setup cannot configure your computer to start windows NT. This may indicate
a problem with the hard disk containing your C: drive or C: may be severely
corrupt. Setup cannot continue.
Press F3 to exit.
CAUSE
The error occurs because Setup cannot write the disk signature. Some
computers have a BIOS option to enable protection of the master boot
record (MBR) and/or boot sector. If this option is turned on, Setup is not
able to write the disk signature or create/delete partitions during
Setup.
RESOLUTION
Disable the CMOS option to protect the MBR and boot sector.