Knowledge Base

New 3C509 Addressing Scheme Requires New Remoteboot Config

Article ID: 139282

Article Last Modified on 11/1/2006


APPLIES TO


This article was previously published under Q139282


SYMPTOMS

The new 3COM 3C509 adapter has a new addressing scheme that requires you create a new remoteboot configuration. The older 3C509 adapters have a VendorName=00608C, and the newer 3C509 adapters have a VendorName=0020AF. If you try to boot the newer adapter with the old configuration, the following error message appears:
unknown client network adapter id

RESOLUTION

To correct this problem, create a new remoteboot configuration as outlined in the Windows NT Server Installation Guide on pages 139-140. Follow the documented steps and add the new 6-digit prefix 0020AF to the VendorName parameter.

Additional query words: prodnt win3x rpl

Keywords: KB139282