Winstone 97 May Fail on Windows NT 4.0
Article ID: 141375
Article Last Modified on 10/31/2006
APPLIES TO
- Microsoft Windows NT Workstation 4.0 Developer Edition
- Microsoft Windows NT Server 4.0 Standard Edition
This article was previously published under Q141375
SYMPTOMS
When run on Windows NT 4.0 with no networking components installed,
Winstone 97 may unexpectedly terminate in the middle of the test. The tests
do not fail when networking components are present.
CAUSE
When no networking components are installed, references to active objects
are released within a short time.
RESOLUTION
Install networking components on Windows NT or obtain the following update.
Microsoft has updated Rpcss.exe to correct the problem. Instructions for
installing it are available from Microsoft support channels or directly
from the following Internet location:
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 4.0 This
problem was corrected in the latest Microsoft Windows NT 4.0 U.S. Service
Pack. For information on obtaining the service pack, query on the following
word in the Microsoft Knowledge Base (without the spaces):
Additional query words: prodnt
Keywords: kbenv KB141375