Knowledge Base

NetBT Fails to Bind to a Large Number of IP Addresses

Article ID: 142880

Article Last Modified on 11/1/2006


APPLIES TO


This article was previously published under Q142880

SYMPTOMS

When a computer running Windows NT is configured with a large number of IP addresses through the registry, NetBT may fail to bind. The following event log error may be generated:
Initialization failed because the driver device could not be created.

CAUSE

Only five IP addresses can be configured per network interface using the TCP/IP configuration screens. However, more may be added using the registry editor. When a large number of IP addresses is assigned to a single Network Interface card, NetBT may fail to bind. Reports on the number of addresses attainable without failure vary from 16 to about 24.

STATUS

Microsoft has confirmed this to be a problem in Windows NT version 3.51. This problem was corrected in the latest Windows NT 3.51 U.S. Service Pack. For information on obtaining the Service Pack, query on the following word in the Microsoft Knowledge Base (without the spaces):

S E R V P A C K




Additional query words: multi homed ISP gibralter Gibraltar IIS internet server multiple addresses more NIC adding multihomed

Keywords: kbnetwork KB142880