RAS Port Instance Names in Performance Monitor Are Corrupted
Article ID: 148846
Article Last Modified on 11/1/2006
APPLIES TO
- Microsoft Windows NT 3.51 Service Pack 2
- Microsoft Windows NT Workstation 4.0 Developer Edition
- Microsoft Windows NT 3.51 Service Pack 2
This article was previously published under Q148846
SYMPTOMS
Normally, the Remote Access Service (RAS) Port Instance names are displayed
as COM1 and COM2. However, in Windows NT 3.51, Performance Monitor displays
the RAS Port Instance names as "C" (without quotation marks).
CAUSE
This problem occurs due to a change in Windows NT Service Pack 2 for ANSI
formatted performance counters. This change causes a problem in the RAS
counter DLL. For more information on a related problem that affects
Microsoft SQL Server and Microsoft SNA Server, please see the following
article here in the Microsoft Knowledge Base:
ARTICLE-ID: 133757
TITLE : Performance Monitor SQLServer-Log Object Corrupted
RESOLUTION
To correct this problem, apply the fix mentioned below.
STATUS
Microsoft has confirmed this to be a problem in Windows NT version 3.51.
This problem was corrected in the latest Windows NT 3.51 U.S. Service
Pack. For information on obtaining the Service Pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
Additional query words: prodnt 3.51 perfmon counters instance names