UNBIND RSP Is Not Passed from SNA Server to a Downstream PU
Article ID: 149801
Article Last Modified on 11/26/2003
APPLIES TO
- Microsoft SNA Server 2.0, when used with:
- Microsoft SNA Server 2.1, when used with:
- Microsoft SNA Server 3.0, when used with:
- Microsoft SNA Server 2.11 Service Pack 1, when used with:
This article was previously published under Q149801
SYMPTOMS
A device set up as a Downstream PU from an SNA Server may hang when you try
to disconnect a session. Tracing on the Downstream PU will show the PU
waiting on an UNBIND response from the host system.
CAUSE
SNA Server is not passing the UNBIND response from the host to the
downstream PU.
RESOLUTION
A hotfix is available from Microsoft Product Support Services. Files that
have been modified to correct this problem are Snaservr.exe and
Trcservr.exe.
STATUS
Microsoft has confirmed this to be a problem in Microsoft SNA Server
versions 2.0, 2.1, 2.11, and 2.11.sp1.
This problem was corrected in the latest Microsoft SNA Server 2.11 U.S.
Service Pack. For information on obtaining the service pack, query on the
following word in the Microsoft Knowledge Base (without the spaces):
Additional query words: sna nt
Keywords: kbbug kbfix kbnetwork KB149801