Patch-ID# 103788-02
Keywords: performance slow oracle SQL-net tcp/ip winsock windows nt hang netbios
Synopsis: PC-NFSpro 2.0: performance issues using Oracle SQL-Net & NetBIOS hangs
Date: Sep/26/96

Solaris Release:  

SunOS Release: 

Unbundled Product: PC-NFSpro

Unbundled Release: 2.0

Relevant Architectures: i386

BugId's fixed with this patch: 1248638 1251597 1258300

Changes incorporated in this version: 1248638 1251597

Patches accumulated and obsoleted by this patch: 

Patches which conflict with this patch:  

Patches required with this patch: 103304-03 
                          NOTE:   on systems running Windows95
Obsoleted by: 

Files included with this patch: 

 NFSW.VXD
 NFSW.386

Problem Description: 

 1248638 - PRO 2.0 using NETBIOS hang when the WindowsNT server goes down
 1251597 - PC-NFSpro 2.0 crashes after 20 min, when connected to a NT server 
           via router.
 1258300 - Pro 2.0 fragments 200 byte packets into 2 packets.

Patch Installation Instructions: 
 
 This patch is packaged as a self-extracting compressed file (10378802.exe).  
 It must be installed from Windows or Windows95.  The setup program backs 
 up the original file(s).  It then installs the new file(s) and a patch 
 uninstall utility. 

 To install, download 10378802.exe to a temporary directory on the PC.  
 
 In Windows95, select "Run" from the "Start" menu.  Enter the path and 
 patch filename (Example: c:\temp\10378802) then select "OK".  

 In Windows 3.1x, select "Run" from the Program Manager "File" menu.  
 Enter the path and patch filename (Example: c:\temp\10378802) then 
 select "OK".  

 The patch will uncompress and start the setup program automatically.  
 Follow the setup program prompts to complete the patch installation.  

 Restart Windows or Windows95.


Patch Removal Instructions:

 In Windows95, click "Start".  Then select "Programs", "Patch 103788-02"
 and click on "uninstallSHIELD".

 In Windows 3.1x, open the "Patch 103788-02" icon in Program Manager
 and double click on "uninstallSHIELD".

 When Uninstall completes, open a DOS box.  In the DOS box: 
 copy c:\windows\system\nfswvxd.bak to c:\windows\system\nfsw.vxd.
 copy c:\windows\system\nfsw386.bak to c:\windows\system\nfsw.386.

 Restart Windows or Windows95.
 

Installation Notes:
 All drive letter and directory name references are PC-NFSpro
 defaults. If you have installed PC-NFSpro or the patch file on 
 a different drive, or in a different directory, substitute your 
 drive and directory names in the example commands above.
