Patch-ID# 101945-06 Keywords: kernel libsocket sockmod procfs kadb nfs RDBMS segmapdev savecore hang Synopsis: SunOS 5.4: jumbo patch for kernel Date: Sep/23/94 Solaris Release: 2.4 SunOS release: 5.4 Unbundled Product: Unbundled Release: Xref: This patch available for x86 as patch 101946 Topic: SunOS 5.4: jumbo patch for kernel (includes libsocket procfs kadb hypersparc nfs) BugId's fixed with this patch: 1173969 1174572 1172979 1172009 1170862 1173626 1172242 1172245 1168398 1166848 1166779 1152922 1165687 1160112 1120225 1152710 1171478 1169909 1167235 1150556 1157053 1175968 1172243 1169686 1174830 1174738 1172998 1175829 1151364 1174847 1177572 Changes incorporated in this version: 1174847 1177572 Relevant Architectures: sparc Patches accumulated and obsoleted by this patch: 101918-01 Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: /kernel/unix /kernel/fs/nfs /kernel/fs/autofs /kernel/drv/cn /usr/lib/libsocket.so.1 /usr/lib/libsocket.a /kernel/strmod/sockmod /kernel/drv/tl /usr/kvm/prtdiag /kadb /kernel/fs/procfs /kernel/fs/nfs /kernel/sys/nfs Problem Description: 1174847 SS5 running 4.1.3U1 - running customer application - HARD HANGS 1177572 Installing Solaris 2.4 ON patch 101945-05 and running OW causes machine to panic The patch to bug ID 1151364 broke OW's consolidation. This happened bacause releasef() changed to have an extra argument. OW shouldn't have been dependent on releasef() which is private to the ON consolidation. Since this problem was not discovered until after the patch was made, it made more sense for ON to produce a new patch which restores releasef() to have its old interface. The interface changed for kaio. A new interface is added called areleasef() which is only used by kaio. This is an enhancement to the workaround created for bug 1161592. Change is local to sun4m/swift cpu code and has NO impact on other non-swift platforms. (from 101945-05) 1174830 savecore on diskless machine didn't generate unix, vmcore is trash 1174738 segmapdev uses condition variables with spin-type mutexes 1172998 x86: auto_lookup(): assertion failure in mutex_exit() on non-existent fs 1175829 booting continuously a diskless machine over network hangs a single CPU machine 1151364 asynchronous I/O in the user level hurts RDBMS performance This is a performance improvement for applications that are using libaio for doing async IO to raw files or devices. There are no API changes, only a new version of libaio.so.1 is installed. One side benefit of this fix is that async IO to tape should now work. This patch to bug 1151364 requires installation of libaio/kaio patch 102020-01 or later) 1175829 -------- During booting diskless over the net, a single CPU system hangs. The cause is that the kernel decides to let PROM handle the profiling timer (L14) interrupt after programming the timer with default values. The PROM waits for profiling timer (L14) to interrrupt but that never happens as timer has been mistakenly stopped (when it was programmed with default values) 1174738 ------- The problem is that lp is a spin-type mutex (the devctx lock) passed by segmapdev_fault. It is illegal, but probably not well documented, to pass a spin-type mutex to cv_wait(). It is also illegal to pass 1 as the arg to mutex_init() for spin-type mutexes. That is a machine-dependent spl argument, and 1 isn't a valid choice (it needs to be a SPL above lock level. 1172998 -------- The panic: panic: mutex_adaptive_exit: mutex not owned by thread, lp f58936 70 owner e0000000 lock 0 waiters 0 curthread f5ce6360 Kernel crash dumps generated on diskless sun4m, sun4d or i86pc systems are not complete. (from 101945-04) 1175968 non-master cpu network interfaces broken on SS1000 1172243 Customer runs application from dumb terminal and system crashes. 1169686 4.1.3 system on network goes down, hangs 2.3 system The problem shows up when a "ps" thread is running through the virtual memory area to get the address space size for a mapped file. The address space lock is held and a get attributes function is called. This initiates an nfs get attribute request. If the machine that the request is made to is not responding the nfs request will block. The address space lock which is held by the blocked ps thread might block other processes on the local machine. Typically when a server goes down all nfs file system activity is blocked on any clients. The nfs operation resumes once the server comes up. In this situation a server is powered down and causes a client to hang. The hang is due to a process pile-up. The client is doing a ps and its thread is holding the address space lock (as_lock) for a running process lets call A. The A process is a mapped file from the server. The client ps thread path has reached rm_assize() which needs to get the file size so it calls VOP_GETATTR() which goes across the wire to the server. This operation goes nowhere because the server is not running. The as_lock held by the ps process is blocking other processes such as init. The solution is not to go over the wire but to return a cached entry for the file size. The change is to define a new attribute flag in vnode.h called ATTR_HINT. The rm_assize() function recognizes will use this flag when it calls VOP_GETATTR(). The nfs getattr function will see that the size of the file is requested and that the passed in flag is ATTR_HINT. It will return the file size from the rnode rather than make a request to the server. Typically when a server goes down all nfs file system activity is blocked on any clients. The nfs operation resumes once the server comes up. In this situation a server is powered down and causes a client to hang. The hang is due to a process pile-up. The client is doing a ps and its thread is holding the address space lock (as_lock) for a running process lets call A. The A process is a mapped file from the server. The client ps thread path has reached rm_assize() which needs to get the file size so it calls VOP_GETATTR() which goes across the wire to the server. This operation goes nowhere because the server is not running. The as_lock held by the ps process is blocking other processes such as init. The solution is not to go over the wire but to return a cached entry for the file size. The change is to define a new attribute flag in vnode.h called ATTR_HINT. The rm_assize() function recognizes will use this flag when it calls VOP_GETATTR(). The nfs getattr function will see that the size of the file is requested and that the passed in flag is ATTR_HINT. It will return the file size from the rnode rather than make a request to the server. Running applications that do I_SETSIG on console, when console is the serial port (i.e not the frame buffer), causes system to crash, when attempting to send signal to a process. Support for SC2000E and SS1000E was patched in the 2.3 and 2.4 releases, and integrated into the 2.5 release. This fix introduced a bug which causes non-zero system boards to have tpe-link-test turned to the incorrect setting. This has the effect of rendering the additional le interfaces non-functional. (from 101945-03) 1169909 Running xlib code in Realtime class causes code to block. in poll() 1167235 panic data fault in strioctl - apparently doing TIOCSPGRP 1150556 System becomes "panic: Overflow of asynchronous faults". This change is for proper handling of memory ECC errors. Previously, an attempt to enqueue an error when the async fault queue was full, resulted in panic: "Overflow of asynchronous faults" The new functionality is: When the queue is full, discard the entry and disable correctable error interrupt generation. Schedule re-enable of interrupt generation (via timeout) after a period of 30 minutes. Message generation is enabled to log information regarding SIMM and faulting address. An additional message is output: Excessive Asynchronous Faults: Possible Memory Deterioration Uncorrectable error occuring while the async fault queue is full results in immediate panic. In addition to queue overflow handling, the rate of error occurance is also monitored. If the rate of errors is such that 256 errors are reported in less than 1 second, ce interrupts are disabled. Re-enable of the ce interrupts is scheduled for 30 minutes (via timeout). Protect with mutex the testing and setting of the session and controlling terminal related flags in the streamhead. Real time stream threads will block in a poll. (from 101945-02) 1174572 Viking workaround enabled on parts that do not need it 1172979 spurious SIGALRM received in test program that forks child processes 1172009 recv() on sockets should return the error only once for SunOS 4.X compatibility 1170862 kadb hangs on MP configuration 1173626 Race condition in ross625_mp_mmu_writepte() where ref/mod bits can be lost 1172242 HyperSPARC Ross_625 A.2/A.3 has bcopy error if destination page is read-only 1172245 iflush code need to be more intelligent for HyperSPARC-MP 1168398 MP CPU start up causes machine to lock up when booting from net 1166848 L1 A and then sync locks up machine 1166779 Add support for dragon+ dual power supply 1152922 prtdiag(1M) should display SBus clock frequency 1165687 reads on acceptor sockets not non-blocking under Solaris 2 when listener is 1160112 socket library accidentally closes file descriptor on error 1120225 recv() returns EPIPE when called with MSG_PEEK 1152710 socket lib in 2.3/2.2 have problems with not clearing bad connections and errno 1171478 socket recv() calls fail with EINVAL due to bad fix in 494 AF_UNIX and AF_INET sockets can sometimes get EPIPE errors for recv(MSG_PEEK). When the socket library sees the EPIPE error it will in some cases close the file descriptor causing the application to get EBADF errors for subsequent operations. A AF_UNIX listening socket can get into a permanant error state (returning EPIPE or ECONNRESET) for any operation until the socket is closed. The non-blocking attribute of a socket endpoint is not transferred from a non-blocking listener endpoint to a accepting endpoint. This causes some socket non-blocking programs to block. This patch fixes the problem by setting the accepting endpoint non-blocking attribute if the listener was non-blocking. Add dual power supply support to SC2000 and SC2000E systems. Systems with dual power supplies will receive warnings on system console when one of the redundant power supplies fails. Modify prtdiag(1M) to indicate SBus Clock frequency. The SC2000E and SS1000E run with 25 MHz SBus clock frequency. The SC2000 and SS1000 run with 20 MHz SBus clock frequency. This change to prtdiag(1M) makes it easy to determine the SBus clock frequency on the system. For versions greater than 2.10 of the Open Boot Prom, L1-A followed by "sync" will sometimes hang. Summary: Patch to support Hypersparc CPU (Colorado) Modules. Below is a brief description of each bug: 1170862 ------- On a Colorado MP machine, if you set up break-points in the kernel try to resume from there, the machine sometimes hangs. Neither L1-A nor taking the keyboard helps. One has to power cycle the machine. 1173626 ------- There is a small window in "ross625_mp_mmu_writepte()" where the reference or modified bits can be lost before cpus are captured 1172242 ------- This is needed for a Ross625 A0-A3 bug where it's possible for the hardware bcopy to write into the destination if the destination is write protected under some circumstances. 1172245: ------- The iflush code for Ross 625 (virtual address-cache cpu) needed to add in per-cpu local flush support instead of doing global broadcast to flush all cpus all the times. 1168398 ------- We have two processors in the system: CPU 0 and CPU 2. CPU 2 executed pause_cpus(), pause_cpus() created a pause_thread for CPU 0 and CPU2 was spinning on safe_list[0] waiting for pause thread for CPU 0 to set safe_list[0] to a 1. But CPU 0 never executed its pause thread. Instead, CPU 0 took a level 14 interrupt and dropped into the PROM and never re-surfaced from the PROM. In SunOS 4.X sockets when a read() or recv*() call returns an error the application can do another read()/recv*() and get an EOF. This patch applies this subtle aspect of socket semantics to SunOS 5.X. This specification of signal actions from the signal(5) manual page was being violated: Setting a signal action to SIG_IGN for a signal that is pending causes the pending signal to be discarded, whether or not it is blocked. Any queued values pending are also discarded, and the resources used to queue them are released and made available to queue other signals. The condition under which the pending signal was not being discarded was the specific case of SIGALRM signals generated by the setitimer(ITIMER_REAL) interface. The malfunction happens in a narrow race condition which will be triggered under intensive setting of a signal handler and setting it to SIG_IGN while the itimer is active. SunOS 5.4 sometimes enables a bug workaround on systems that do not need it. (from 101945-01) 1173969 MT process doesn't stop on multi processor systems dbx appears to malfunction when controlling a multithreaded process that does many fork1()s. The bug is in the system, not dbx. Also, stopping dbx with a jobcontrol signal from the terminal, ^Z, while it is controlling a multithreaded process will cause the multithreaded process to becomed permanently stopped. (from 101918-01) 1157053 ESC8146 System panics when doing a copy to NFS file system mounted across FDDI-S Cause of problem is due to non-aligned transfers. The memory address alignment trap happened in xdr_writeargs() when copying data in a loop. The address was not on a long word boundary, it was on a word boundary. nfs_feedback() can adjust the transfer address and size for a request such as for a retransmission. The xdr_writeargs() can make use of bcopy(). The xdr_writeargs() is in file nfs_xdr.c. There are a few other functions in this file that do a similar copy operation that should be changed to use bcopy. Patch Installation Instructions: -------------------------------- Generic 'installpatch' and 'backoutpatch' scripts are provided within each patch package with instructions appended to this section. Other specific or unique installation instructions may also be necessary and should be described below. Special Install Instructions: ----------------------------- none ----------------------------- none Instructions to install patch using "installpatch" -------------------------------------------------- 1. Become super-user. 2. Apply the patch by typing: installpatch where is the directory containing installpatch, and is the directory containing the patch itself. Example: # cd /tmp/123456-01 # ./installpatch . 3. If any errors are reported, see "Patch Installation Errors" in the Command Descriptions section below. Rebooting the system or restarting the application after a successful patch installation is usually necessary to utilize patch. NOTE: On client server machines the patch package is NOT applied to existing clients or to the client root template space. Therefore, when appropriate, ALL CLIENT MACHINES WILL NEED THE PATCH APPLIED DIRECTLY USING THIS SAME INSTALLPATCH METHOD ON THE CLIENT. See the next section for instructions for installing a patch on a client. Instructions for installing a patch on a dataless client -------------------------------------------------------------------- 1. Before applying the patch, the following command must be executed on the server to give the client read-only, root access to the exported /usr file system so that the client can execute the pkgadd command: share -F nfs -o ro,anon=0 /export/exec//usr The command: share -F nfs -o ro,root= \ /export/exec//usr accomplishes the same goal, but only gives root access to the client specified in the command. 2. Login to the client system and become super-user. 3. Continue with step 2 in the "Instructions to install patch using installpatch" section above. Instructions for installing a patch on a diskless client -------------------------------------------------------------------- ** To install a patch on a diskless client, you may either follow the instructions for installing on a dataless client (that is, you may logon to the client and install the patch), or you may use the following instructions to install the patch while on the server. 1. Find the complete path for the root directory of the diskless client. 2. Install the patch normally, but add the command option -R to the command line. should be the completely specified. Example: # cd /tmp/123456-01 # ./installpatch -R /export/root/client1 . Instructions for backing out a patch using "backoutpatch" ----------------------------------------------------------- 1. Become super-user. 2. Change directory to /var/sadm/patch: cd /var/sadm/patch 3. Backout patch by typing: /backoutpatch where is the patch number. Example: # cd /var/sadm/patch # 123456-01/backoutpatch 123456-01 4. If any errors are reported, see "Patch Backout Errors" in the Command Descriptions section below. Instructions for backing out a patch on a dataless client ---------------------------------------------------------- 1. Give the client root access to /usr as specified in the installpatch section. 2. Logon to the client and follow backoutpatch instructions as specified above. Instructions for backing out a patch on a diskless client ----------------------------------------------------------- ** To backout a patch on a diskless client, you may either follow the instructions for backout on a dataless client (that is, you may logon to the client and backout the patch), or you may use the following instructions to backout the patch while on the server. 1. Find the complete path for the root directory of the diskless client. 2. Backout the patch normally, but add the command option -R to the command line. should be the completely specified. Example: # cd /export/root/client1/var/sadm/patch # ./123456-01/backoutpatch -R /export/root/client1 123456-01 Instructions for identifying patches installed on system: ---------------------------------------------------------- Patch packets that have been installed can be identified by using the -p option. To find out which patches are installed on a diskless client, use both the -R option and the -p option, where is the fully specified path to the client's root directory. #cd /tmp/123456-01 #./installpatch -p #./installpatch -R /export/root/client1 -p Also note that the command "showrev -p" will show the patches installed on the local machine, but will not show patches installed on clients. Command Descriptions -------------------- NAME installpatch - apply patch package to Solaris 2.x system backoutpatch - remove patch package, restore previously saved files SYNOPSIS installpatch [-udpV] [-S ] backoutpatch [-fV] [-S ] DESCRIPTION These installation and backout utilities apply only to Solaris 2.x associated patches. They do not apply to Solaris 1.x associated patches. These utilities are currently only provided with each patch package and are not included with the standard Solaris 2.x release software. OPTIONS installpatch: -u unconditional install, turns off file validation. Allows the patch to be applied even if some of the files to be patched have been modified since original installation. -d Don't back up the files to be patched. This means that the patch CANNOT BE BACKED OUT. -p Print a list of the patches currently applied -V Print script version number -S Specify an alternate service (e.g. Solaris_2.3) for patch package processing references. -R Specify an alternate package installation root. Most useful for installing patches on diskless clients while logged on to the server. backoutpatch: -f force the backout regardless of whether the patch was superseded -V print version number only -S Specify an alternate service (e.g. Solaris_2.3) for patch package processing references. -R Specify an alternate package installation root. Most useful for removing patches on diskless clients while logged on to the server. DIAGNOSTICS Patch Installation Errors: -------------------------- Error message: The prepatch script exited with return code . Installpatch is terminating. Explanation and recommended action: The prepatch script supplied with the patch exited with a return code other than 0. Run a script trace of the installpatch and find out why the prepatch had a bad return code. Fix the problem and re-run installpatch. To execute a script trace: # sh -x ./installpatch . > /tmp/patchout 2>&1 The file /tmp/patchout will list all commands executed by installpatch. You should be able to determine why your prepatch script failed by looking through the /tmp/patchout file. If you still can't determine the reason for failure, contact customer service. Error message: The postpatch script exited with return code . Backing out patch. Explanation and recommended action: The postpatch script provided with the patch exited with an error code other than 0, and the patch has not previously been applied. Installpatch will execute backoutpatch to return the system to its pre-patched state. Create a script trace of the installpatch (see above) and find out why the postpatch script failed. Correct and re-execute installpatch. If you are unable to determine why the postpatch script failed, contact customer service. Error message: The postpatch script exited with return code . Not backing out patch because this is a re-installation. The system may be in an unstable state! Installpatch is terminating. Explanation and recommended action: The postpatch script provided with the patch exited with an error code other than 0. Because this is a re-installation of a patch, installpatch will not automatically backout the patch. You may backout the patch manually using the backoutpatch command, then generate a script trace of the installpatch as described above. Find out why the postpatch failed, correct the problem, and re-install the patch. If you are unable to determine why the postpatch script failed, contact customer service. Error message: Patch has already been applied. Explanation and recommended action: This patch has already been applied to the system and no additional patch packages would be added due to a re-installation. If the patch has to be reapplied for some reason, backout the patch and then reapply it. Error message: Symbolic link in package Symbolic links can't be part of a patch. Installpatch is terminating. Explanation and recommended action: The patch was incorrectly built. Contact customer service to get a new patch. Error message: This patch is obsoleted by patch which has already been applied to this system. Patch installation is aborted. Explanation and recommended action: Occasionally, a patch is replaced by a new patch which incorporates the bug fixes in the old patch and supplies additional fixes also. At this time, the earlier patch is no longer made available to users. The second patch is said to "obsolete" the first patch. However, it is possible that some users may still have the earlier patch and try to apply it to a system on which the later patch is already applied. If the obsoleted patch were allowed to be applied, the additional fixes supplied by the later patch would no longer be available, and the system would be left in an inconsistent state. This error message indicates that the user attempted to install an obsoleted patch. There is no need to apply this patch because the later patch has already supplied the fix. Error Message: None of the packages to patch are installed on this system. Explanation and recommended action: The original packages for this patch have not been installed and therefore the patch cannot be applied. The original packages need to be installed before applying the patch. Error message: This patch is not applicable to client systems. Explanation and recommended action: The patch is only applicable to servers and standalone machines. Attempting to apply this patch to a client system will have no effect on the system. Error message: The -S and -R arguments are mutually exclusive. Explanation and recommended action: You have specified both a non-native service to patch, and a package installation root. These two arguments are mutually exclusive. If patching a non-native usr partition, the -S option should be used to patch all clients using that service. If patching a client's root partition (either native or non-native), the -R option should be used. Error message: The service cannot be found on this system. Explanation and recommended action: You have specified a non- native service to patch, but the specified service is not installed on your system. Correctly specify the service when applying the patch. Error message: The Package Install Root directory cannot be found on this system. Explanation and recommended action: You have specified a directory that is either not mounted, or does not exist on your system. Specify the directory correctly when applying the patch. Error message: The /usr/sbin/pkgadd command is not executable. Explanation and recommended action: The /usr/sbin/pkgadd command cannot be executed. The most likely cause of this is that installpatch is being run on a diskless or dataless client and the /usr file system was not exported with root access to the client. See the section above on "Instructions for installing a patch on a diskless or dataless client". Error message: packages are not proper patch packages. Explanation and recommended action: The patch directory supplied as an argument to installpatch did not contain the expected package format. Verify that the argument supplied to installpatch is correct. Error message: The following validation error was found: Explanation and recommended action: Before applying the patch, the patch application script verifies that the current versions of the files to be patched have the expected fcs checksums and attributes. If a file to be patched has been modified by the user, the user is notified of this fact. The user then has the opportunity to save the file and make a similar change to the patched version. For example, if the user has modified /etc/inet/inetd.conf and /etc/inet/inetd.conf is to be replaced by the patch, the user can save the locally modified /etc/inet/inetd.conf file and make the same modification to the new file after the patch is applied. After the user has noted all validation errors and taken the appropriate action for each one, the user should re-run installpatch using the "-u" (for "unconditional") option. This time, the patch installation will ignore validation errors and install the patch anyway. Error message: Insufficient space in /var/sadm/patch to save old files. Explanation and recommended action: There is insufficient space in the /var/sadm/patch directory to save old files. The user has two options for handling this problem: (1) generate additional disk space by deleting unneeded files, or (2) override the saving of the old files by using the "-d" (do not save) option when running installpatch. However if the user elects not to save the old versions of the files to be patched, backoutpatch CANNOT be used. One way to regain space on a system is to remove the save area for previously applied patches. Once the user has decided that it is unlikely that a patch will be backed out, the user can remove the files that were saved by installpatch. The following commands should be executed to remove the saved files for patch xxxxxx-yy: cd /var/sadm/patch/xxxxxx-yy rm -r save/* rm .oldfilessaved After these commands have been executed, patch xxxxxx-yy can no longer be backed out. Error message: Save of old files failed. Explanation and recommended action: Before applying the patch, the patch installation script uses cpio to save the old versions of the files to be patched. This error message means that the cpio failed. The output of the cpio would have been preceded this message. The user should take the appropriate action to correct the cpio failure. A common reason for failure will be insufficient disk space to save the old versions of the files. The user has two options for handling insufficient disk space: (1) generate additional disk space by deleting unneeded files, or (2) override the saving of the old files by using the "-d" option when running installpatch. However if the user elects not to save the old versions of the files to be patched, the patch CANNOT be backed out. Error message: Pkgadd of package failed with error code . See /tmp/log. for reason for failure. Explanation and recommended action: The installation of one of patch packages failed. Installpatch will backout the patch to leave the system in its pre-patched state. See the log file for the reason for failure. Correct the problem and re-apply the patch. Error message: Pkgadd of package failed with error code . Will not backout patch...patch re-installation. Warning: The system may be in an unstable state! See /tmp/log. for reason for failure. Explanation and recommended action: The installation of one of the patch packages failed. Installpatch will NOT backout the patch. You may manually backout the patch using backoutpatch, then re-apply the entire patch. Look in the log file for the reason pkgadd failed. Correct the problem and re-apply the patch. Patch Installation Messages: --------------------------- Note: the messages listed below are not necessarily considered errors as indicated in the explanations given. These messages are, however, recorded in the patch installation log for diagnostic reference. Message: Package not patched: PKG=SUNxxxx Original package not installed Explanation: One of the components of the patch would have patched a package that is not installed on your system. This is not necessarily an error. A Patch may fix a related bug for several packages. Example: suppose a patch fixes a bug in both the online-backup and fddi packages. If you had online-backup installed but didn't have fddi installed, you would get the message Package not patched: PKG=SUNWbf Original package not installed This message only indicates an error if you thought the package was installed on your system. If this is the case, take the necessary action to install the package, backout the patch (if it installed other packages) and re-install the patch. Message: Package not patched: PKG=SUNxxx ARCH=xxxxxxx VERSION=xxxxxxx Architecture mismatch Explanation: One of the components of the patch would have patched a package for an architecture different from your system. This is not necessarily an error. Any patch to one of the architecture specific packages may contain one element for each of the possible architectures. For example, Assume you are running on a sun4m. If you were to install a patch to package SUNWcar, you would see the following (or similar) messages: Package not patched: PKG=SUNWcar ARCH=sparc.sun4c VERSION=11.5.0,REV=2.0.18 Architecture mismatch Package not patched: PKG=SUNWcar ARCH=sparc.sun4d VERSION=11.5.0,REV=2.0.18 Architecture mismatch Package not patched: PKG=SUNWcar ARCH=sparc.sun4e VERSION=11.5.0,REV=2.0.18 Architecture mismatch Package not patched: PKG=SUNWcar ARCH=sparc.sun4 VERSION=11.5.0,REV=2.0.18 Architecture mismatch The only time these messages indicate an error condition is if installpatch does not correctly recognize your architecture. Message: Package not patched: PKG=SUNxxxx ARCH=xxxx VERSION=xxxxxxx Version mismatch Explanation: The version of software to which the patch is applied is not installed on your system. For example, if you were running Solaris 5.3, and you tried to install a patch against Solaris 5.2, you would see the following (or similar) message: Package not patched: PKG=SUNWcsu ARCH=sparc VERSION=10.0.2 Version mismatch This message does not necessarily indicate an error. If the version mismatch was for a package you needed patched, either get the correct patch version or install the correct package version. Then backout the patch (if necessary) and re-apply. Message: Re-installing Patch. Explanation: The patch has already been applied, but there is at least one package in the patch that could be added. For example, if you applied a patch that had both Openwindows and Answerbook components, but your system did not have Answerbook installed, the Answerbook parts of the patch would not have been applied. If, at a later time, you pkgadd Answerbook, you could re-apply the patch, and the Answerbook components of the patch would be applied to the system. Message: Installpatch Interrupted. Installpatch is terminating. Explanation: Installpatch was interrupted during execution (usually through pressing ^C). Installpatch will clean up its working files and exit. Message: Installpatch Interrupted. Backing out Patch... Explanation: Installpatch was interrupted during execution (usually through pressing ^C). Installpatch will clean up its working files, backout the patch, and exit. Patch Backout Errors: --------------------- Error message: prebackout patch exited with return code . Backoutpatch exiting. Explanation and corrective action: the prebackout script supplied with the patch exited with a return code other than 0. Generate a script trace of backoutpatch to determine why the prebackout script failed. Correct the reason for failure, and re-execute backoutpatch. Error message: postbackout patch exited with return code . Backoutpatch exiting." Explanation and corrective action: the postbackout script supplied with the patch exited with a return code other than 0. Look at the postbackout script to determine why it failed. Correct the failure and, if necessary, RE-EXECUTE THE POSTBACKOUT SCRIPT ONLY. Error message: Only one service may be defined. Explanation and corrective action: You have attempted to specify more than one service from which to backout a patch. Different services must have their patches backed out with different invocations of backoutpatch. Error message: The -S and -R arguments are mutually exclusive. Explanation and recommended action: You have specified both a non-native service to backout, and a package installation root. These two arguments are mutually exclusive. If backing out a patch from a non-native usr partition, the -S option should be used. If backing out a patch from a client's root partition (either native or non-native), the -R option should be used. Error message: The service cannot be found on this system. Explanation and recommended action: You have specified a non- native service from which to backout a patch, but the specified service is not installed on your system. Correctly specify the service when backing out the patch. Error message: Only one rootdir may be defined. Explanation and recommended action: You have specified more than one package install root using the -R option. The -R option may be used only once per invocation of backoutpatch. Error message: The directory cannot be found on this system. Explanation and recommended action: You have specified a directory using the -R option which is either not mounted, or does not exist on your system. Verify the directory name and re-backout the patch. Error message: Patch has not been successfully applied to this system. Explanation and recommended action: You have attempted to backout a patch that is not applied to this system. If you must restore previous versions of patched files, you may have to restore the original files from the initial installation CD. Error message: Patch has not been successfully applied to this system. Will remove directory Explanation and recommended action: You have attempted to back out a patch that is not applied to this system. While the patch has not been applied, a residual /var/sadm/patch/ (perhaps from an unsuccessful installpatch) directory still exists. The patch cannot be backed out. If you must restore old versions of the patched files, you may have to restore them from the initial installation CD. Error message: This patch was obsoleted by patch . Patches must be backed out in the order in which they were installed. Patch backout aborted. Explanation and recommended action: You are attempting to backout patches out of order. Patches should never be backed-out out of sequence. This could undermine the integrity of the more current patch. Error message: Patch was installed without backing up the original files. It cannot be backed out. Explanation and recommended action: Either the -d option of installpatch was set when the patch was applied, or the save area of the patch was deleted to regain space. As a result, the original files are not saved and backoutpatch cannot be used. The original files can only be recovered from the original installation CD. Error message: pkgrm of package failed return code . See /var/sadm/patch//log for reason for failure. Explanation and recommended action: The removal of one of patch packages failed. See the log file for the reason for failure. Correct the problem and run the backout script again. Error message: Restore of old files failed. Explanation and recommended action: The backout script uses the cpio command to restore the previous versions of the files that were patched. The output of the cpio command should have preceded this message. The user should take the appropriate action to correct the cpio failure. KNOWN PROBLEMS: On client server machines the patch package is NOT applied to existing clients or to the client root template space. Therefore, when appropriate, ALL CLIENT MACHINES WILL NEED THE PATCH APPLIED DIRECTLY USING THIS SAME INSTALLPATCH METHOD ON THE CLIENT. See instructions above for applying patches to a client. A bug affecting a package utility (eg. pkgadd, pkgrm, pkgchk) could affect the reliability of installpatch or backoutpatch which uses package utilities to install and backout the patch package. It is recommended that any patch that fixes package utility problems be reviewed and, if necessary, applied before other patches are applied. Such existing patches are: 100901 Solaris 2.1 101122 Solaris 2.2 101331 Solaris 2.3 SEE ALSO pkgadd, pkgchk, pkgrm, pkginfo, showrev, cpio