1 Introduction
This instruction concerns alarm handling for the Application Counters, Fault In Subscriber Statistic Application alarm.
1.1 Alarm Description
This alarm is raised when it is not possible to get application counters.
The alarm is issued in the following situations:
- Failing to find source of application counters information.
- Faulty or missing configuration.
- Impossible to store collected application counters values.
- Impossible to execute the stored procedure.
The possible alarm causes and the corresponding fault reasons, fault locations and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Failing to find source of application counters information. |
The system cannot determine from where to retrieve counter information or there is no source of counter information. |
No information about where to extract/collect/gather counter information. [Couldn't get slave SDL list or master list.] |
BC cluster |
No application counters generation for affected applications counters. |
|
No available slave replica for this DSG. [Couldn't get slave SDL list or master list.] |
DSG without slave replica | |||
|
No master replica for this DSG. [There are some nodes without master] |
Masterless DSG | |||
|
Faulty or missing configuration. |
The configuration for application counters is missing or incorrect. |
The application counters configuration file does not exist. [The application counter's configuration file does not exist.] |
Application counters configuration | |
|
The counters configuration file is present but the information there is incorrect. [The expected application counter's database/table/column is not found.] |
Application counters configuration | |||
|
Impossible to store collected application counters values. |
Application values are calculated but can’t be stored because of communication problems or other kind of problems. |
Impossible to store generated application counters in the PLDB. [Couldn't update PL counters table.] |
PLDB master | |
|
The communication with the master PLDB replica cannot be established. [Couldn't connect to PL tables.] |
||||
|
Impossible to execute the stored procedure. |
An error occurred in the PLDB or DSG involved in the application counters process. It is not possible to execute the stored procedure allocated in the access server. |
It is impossible to execute the stored procedure in PLDB. [error application counters trap for PL.] |
PLDB access server on master replica | |
|
It is impossible to execute the stored procedure in a DSG. [error application counters trap for DS#{dsg}.] |
DS access server on slave replica |
- Note:
- An alarm can appear as a result of maintenance activity.
The following are the consequences for the node if the alarm is
not solved:
There is no application counters generation for the
affected applications counters. Affected application counters are
counters reported in alarm descriptions.
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
Yes |
|
Module |
APPLICATION-COUNTERS |
|
Error Code |
1 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raise. |
|
Resource ID |
.1.3.6.1.4.1.193.169.8.1.<DG>.<CGL>.<CG> |
|
Alarm Model Description |
Fault retrieving subscriber statistics, Application Counters. |
|
Alarm Active Description |
Application Counters: fault retrieving subscriber statistics for <DS_group> in Group counter <FileName> (<cause>). |
|
ITU Alarm Event Type |
processingErrorAlarm (4) |
|
ITU Alarm Probable Cause |
applicationSubsystemFailure (158) |
|
ITU Alarm Perceived Severity |
(4) - Major |
|
Originating source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which the alarms are raised. |
In Table 2, the indicated variables are as follows:
- <DG> is the Data Store Unit Group (DSG) or the Processing Layer Database (PLDB) whose application counters could not be retrieved, starting from 0 (PLDB) to the maximum number of DSGs in the system.
- <CGL> is the number of characters in the counter group name.
- <CG> is the
name of the counter group to process. The name is listed as dot separated
letters in ASCII code.
For example:
71.82.80.95.65.76.76.66.83.71 stands for GRP_ALLBSG.
- <DS_group> is :
- <FileName> is the name of the configuration file that contains the counter group to process.
- <cause> is
an optional additional description field and its value is one of the
following:
- Couldn't get slave SDL list or master list.
- The application counter's configuration file does not exist.
- The expected application counter's database/table/column is not found.
- Couldn't update PL counters table.
- Couldn't connect to PL tables.
- There are some nodes without master.
- error application counters trap for PL.
- error application counters trap for DS#{dsg}.
- {dsg} is the number of the affected DSG.
- Note:
- Even when the cause of the alarm is not located in the PLDB, nor in the DSG (such as "Failing to find source of application counters information" or "Faulty or missing configuration"), the Resource ID field contains <DG>=0, while the value of <DS_group> in the Alarm Active Description field is PLDB.
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents, depending on the type of application counters installed:
- Home Location Register Front End (HLR-FE) 16A Installation Instruction ("Installation Instruction for HLR Application in UDC"), regarding Installation script and application counters package (the Container File package is sometimes called "Software Records") download and instructions on how to install application counters.
- Home Subscriber Server FE (HSS-FE) Software Installation Instruction, regarding Installation script and application counters package download and instructions on how to install and check that the application counters are correctly installed.
- Service-Aware Policy Controller (SAPC) Installation Instruction, section "Configuring SAPC Application Counters in External Database (CUDB)" regarding implementation of the application counters and checking that the application counters are correctly installed.
And the following CUDB documents:
- CUDB Node Fault Management Configuration Guide, Reference [1], regarding alarm configuration.
- CUDB Application Counters, Reference [2].
- System Safety Information, Reference [10].
- Personal Health and Safety Information, Reference [11].
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
This section describes the procedure to follow when this alarm is received.
- Note:
- Publishing interval is usually 15 minutes (default value).
2.1 Actions for "Couldn't Get Slave SDL List or Master List"
Do the following:
- Check if the Control, Blackboard Coordination
Cluster Down alarm is raised. In case it is raised,
refer to Control, Blackboard Coordination Cluster Down, Reference [3] on how to proceed.
After the above alarm is cleared, wait for another publishing interval. Then go to Step 3.
- Check if the Storage Engine, DS Cluster Node Down alarm
is raised. In case it is raised, refer to Storage Engine, DS Cluster
Node Down on how to proceed.
After the above alarm is cleared, wait for another publishing interval. Then go to Step 3.
- If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
2.2 Actions for "Faulty or Missing Configuration"
For the following causes:
- The application counter's configuration file does not exist.
- The expected application counter's database/table/column is not found.
Do the following:
- Perform re-installation steps as described in Section 3.1.
Wait for another publishing interval.
If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
2.3 Actions for "Impossible to Store Collected Application Counters Values"
For the following causes:
Do the following:
- Consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
2.4 Actions for "There Are Some Nodes without Master"
Do the following:
- Check if the Storage Engine, No Available
Master Replica for DS alarm or the Storage
Engine, No Available Master Replica for PLDB alarm is
raised. In case it is raised, refer to Storage Engine, No Available Master Replica for DS, Reference [4] or Storage Engine, No Available Master Replica for PLDB, Reference [5] on how to proceed for each alarm.
After the above alarm is cleared, wait for another publishing interval.
If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
2.5 Actions for "Error Application Counters Trap for PL"
Do the following:
- Check if the Storage Engine, PLDB Cluster
Node Down alarm is raised. In case it is raised, refer
to Storage Engine, PLDB Cluster Node Down, Reference [6] on how to proceed.
After the above alarm is cleared, wait for another publishing interval. Then go to Step 4.
- Perform restoration steps as described in Section 3.2.
- Note:
- It is possible that the cluster has been restored as part of a system data restore procedure or following a flawed unit or group data restore procedure at an earlier point in time.
After stored procedures restoration, wait for another publishing interval. If the alarm is cleared, no further steps are needed.
- Perform re-installation steps as described in Section 3.1.
Wait for another publishing interval.
- If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
2.6 Actions for "Error Application Counters Trap for DSG"
Do the following:
- Check if the Storage Engine, DS Cluster Node
Down alarm is raised. In case it is raised, refer to Storage Engine, DS Cluster Node Down, Reference [7] on how to proceed.
After the above alarm is cleared, wait for another publishing interval. Then go to Step 4.
- Perform restoration steps as described in Section 3.2.
- Note:
- It is possible that the cluster has been restored as part of a system data restore procedure or following a flawed unit or group data restore procedure at an earlier point in time.
After stored procedures restoration, wait for another publishing interval. If the alarm is cleared, no further steps are needed.
- Perform re-installation steps as described in Section 3.1.
Wait for another publishing interval.
- If the alarm does not cease, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
3 Generic Recovery Steps
3.1 Application Counters Re-Installation Steps
3.1.1 Applications Counters Installed Using Application FE Installation Scripts
Make sure the correct revisions of the installation script and the application counters package (the Container File package is sometimes called "Software Records") is available for re-installation.
- Note:
- For some application FE and schema revision should be checked.
For correct revisions, refer to the "Product Revision Information" document in the CPI of the corresponding application FE.
Uninstall the current script and package, and use the correct revisions of the installer script and application counters package to install them again.
- Note:
3.1.2 Manually Installed Application Counters
If the application counters are to be re-installed manually, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
3.2 Stored Procedures Restoration Steps
After restoration (Data Restore), it is necessary to recreate stored procedures. If --restore-stored-procedures | -s options were not used during cudbManageStore --order restore, it is necessary to restore them now.
- Note:
- The Self-Ordered Backup and Restore procedure automatically recreates stored procedures.
To restore the stored procedures and application counter procedures on the local PLDB, enter the following command:
# cudbManageStore -p -o restorestoredprocedures
To restore the stored procedures and application counter procedures on a DS, enter the following command:
# cudbManageStore -d <dsId> -o restorestoredprocedures
- Note:
- To determine the <dsId>, check the value of the cudbLocalDsId configuration attribute for the CudbLocalDs object for which the dsGroupId attribute corresponds to the affected DSG. For more information about these configuration settings, refer to the "Class CudbLocalDs" section of CUDB Node Configuration Data Model Description, Reference [8]. For more information on how to connect to the CUDB configuration CLI and check configuration settings, refer to the "Configuration Modification Procedure" section of CUDB Node Configuration Data Model Description, Reference [8].