1 Introduction
This instruction concerns alarm handling for the Licensing, Capacity Usage Threshold Reached, Warning alarm.
1.1 Alarm Description
This alarm is raised when the number of reserved capacity in a capacity license approaches the Warning threshold. The default value of the Warning threshold is 80% of the licensedCapacityLimit parameter.
The alarm is issued in the following situations:
- The capacity usage has reached the Warning threshold for the HLR Profile.
- The capacity usage has reached the Warning threshold for the HSS-IMS Profile.
- The capacity usage has reached the Warning threshold for the HSS-EPC Profile.
- The capacity usage has reached the Warning threshold for the AUC Profile.
- The capacity usage has reached the Warning threshold for the Small Generic Profile.
- The capacity usage has reached the Warning threshold for the Medium Generic Profile.
- The capacity usage has reached the Warning threshold for the Large Generic Profile.
- The capacity usage has reached the Warning threshold for the IoT Profile.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The Warning threshold of the capacity profile has been passed. |
The capacity usage threshold has been reached. |
The requested capacity has passed the Warning threshold defined in the capacity license. |
License Manager |
Potential violation of license agreements, if the number of reserved capacity continues to increase and reaches the limit. |
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
Yes |
|
Module |
LICENSING |
|
Error Code |
5 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raised. |
|
Resource ID |
1.3.6.1.4.1.193.169.14.2.3.<# SUB_LICENSE_SUFFIX> |
|
Alarm Model Description |
License Management, Licensing |
|
Alarm Active Description |
Capacity Usage Threshold Reached for <#LICENSE_TYPE>, Warning |
|
ITU Alarm Event Type |
qualityOfServiceAlarm (3) |
|
ITU Alarm Probable Cause |
thresholdCrossed (549) |
|
ITU Alarm Perceived Severity |
(6) – Warning |
|
Originating source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which the alarms are raised. |
The available values of the <#SUB_LICENSE_SUFFIX> and <#LICENSE_TYPE> variables
shown in Table 2 are listed below. The
list follows the below format:
"<#SUB_LICENSE_SUFFIX>" for the <#LICENSE_TYPE>.
- "2" for the HLR Profile.
- "3" for the HSS-IMS Profile.
- "4" for the HSS-EPC Profile.
- "5" for the AUC Profile.
- "6" for the Small Generic Profile.
- "7" for the Medium Generic Profile.
- "8" for the Large Generic Profile.
- "9" for the IoT Profile.
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
Before starting this procedure, ensure that you have read the following documents:
- CUDB Node Fault Management Configuration Guide, Reference [1], regarding alarm configuration.
- System Safety Information, Reference [4]
- Personal Health and Safety Information, Reference [5]
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
If the alarm is raised, then refer to the License Management, Capacity Usage Threshold Reached, Reference [3] document for the procedure to perform.
- Note:
- Perform only the actions that are applicable for LM deployments using ELIM license key files. The applicable severity is "Warning".
Glossary
For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [2].
Reference List
| CUDB Documents |
|---|
| [1] CUDB Node Fault Management Configuration Guide. |
| [2] CUDB Glossary of Terms and Acronyms. |
| Other Ericsson Documents |
|---|
| [3] License Management, Capacity Usage Threshold Reached. |
| [4] System Safety Information. |
| [5] Personal Health and Safety Information. |

Contents