SOAP Notifications, Endpoint Unreachable
Ericsson Centralized User Database

Contents

1Introduction
1.1Alarm Description
1.2Prerequisites

2

Procedure

Glossary

Reference List

1   Introduction

This instruction concerns alarm handling for the SOAP Notifications, Endpoint Unreachable alarm.

1.1   Alarm Description

This alarm is raised when a configured Notifications endpoint is unavailable or unresponsive, that is, the endpoint is not answering with an HTTP/Simple Object Access Protocol (SOAP) response even after several attempts.

Due to the synchronous nature of SOAP messages and to avoid having blocked resources waiting for unresponsive target destinations, the Notifications process will detect unresponsive endpoints and will put a cap on the resources allocated to sending notifications to such endpoints, until they start responding again. The alarm will be cleared automatically when the endpoint starts responding again.

The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.

Table 1    Alarm Causes

Alarm Cause

Description

Fault Reason

Fault Location

Impact

Detected unresponsive Notifications endpoint.

Sending rate towards the faulty endpoint is reduced by assigning less resources to communicating with the unresponsive destination.

Unreachable endpoint due to:


  • networking problems, or

  • misconfigured endpoint Uniform Resource Identifiers (URIs), or

  • improper routing to reach the destination endpoint.

Notification endpoint, network, or Notifications event configuration.

Notifications rate is lowered toward the unresponsive endpoint by assigning less resources to minimize impacts for sending messages to the rest of available destinations.

The alarm attributes are listed and explained in Table 2.

Table 2    Alarm Attributes

Attribute Name

Attribute Value

Auto Cease

Yes

Module

SOAP NOTIFICATIONS

Error Code

1

Timestamp First

Date and time when the alarm was raised for the first time.

Repeated Counter

Number which indicates how many times the alarm was raised.

Timestamp Last

Date and time of the most recent alarm raised.

Resource ID

1.3.6.1.4.1.193.169.15.1.<EndpointURI>

Alarm Model Description

Endpoint Unreachable, SOAP Notifications

Alarm Active Description

SOAP Notifications: Endpoint unreachable at URI <Endpoint URI>

ITU Alarm Event Type

communicationsAlarm (2)

ITU Alarm Probable Cause

connectionEstablishmentError (22)

ITU Alarm Perceived Severity

(5) – Minor

Originating Source IP

Node IP where the alarm was raised.

Sequence Number

Number which indicates the order in which alarms were raised.

In Table 2, the indicated variables are as follows:

1.2   Prerequisites

This section provides information on the documents, tools and conditions that apply to the procedure.

1.2.1   Documents

Before starting this procedure, ensure that you have read the following documents:

1.2.2   Tools

Not applicable.

1.2.3   Conditions

Not applicable.

2   Procedure

If the alarm is raised, do the following:

  1. If the alarm is not cleared automatically in a short period of time, check if the endpoint URI is configured correctly in the Notifications configuration. Refer to the Class CudbNotificationEndPoint section of CUDB Node Configuration Data Model Description, Reference [3].
  2. If the endpoint URI configuration was correct or it has been corrected in Step 1 but the alarm is still raised, consult the next level of maintenance support.

Glossary

For the terms, definitions, acronyms and abbreviations used in this document, refer to CUDB Glossary of Terms and Acronyms, Reference [4].


Reference List

CUDB Documents
[1] CUDB Node Fault Management Configuration Guide.
[2] CUDB Notifications.
[3] CUDB Node Configuration Data Model Description.
[4] CUDB Glossary of Terms and Acronyms.
Other Ericsson Documents
[5] System Safety Information.
[6] Personal Health and Safety Information.