1 Introduction
This instruction concerns alarm handling for the Storage Engine, Deleted Data Due to Reconciliation alarm.
1.1 Alarm Description
The alarm is issued if data has been deleted from the Data Store (DS) data partition due to a data reconciliation process.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
The automated reconciliation process has deleted data to achieve consistency. |
Data was deleted from the Data Store (DS) data partition due to a data reconciliation process to achieve consistency. |
No fault, a data reconciliation task is ongoing or pending. |
No impact, the reconciliation task must be finished. |
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
No |
|
Module |
STORAGE-ENGINE |
|
Error Code |
12 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raised. |
|
Resource ID |
.1.3.6.1.4.1.193.169.1.2.12. <DG> |
|
Alarm Model Description |
Deleted data due to reconciliation, Storage Engine |
|
Alarm Active Description |
Storage Engine (DS-group # <DG> ): Deleted data due to reconciliation. |
|
ITU Alarm Event Type |
communicationsAlarm (2) |
|
ITU Alarm Probable Cause |
databaseInconsistency (160) |
|
ITU Alarm Perceived Severity |
(5) – Minor |
|
Originating Source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which alarms were raised. |
In Table 2, the indicated variables are as follows:
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide.
1.2 Prerequisites
This section provides information on the documents, tools and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following documents:
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
If the alarm is raised, do the following:
Steps

Contents