1 Introduction
This instruction concerns alarm handling for the Storage Engine, Backup Fault In DS alarm.
1.1 Alarm Description
The alarm is issued when a backup procedure fails in a Data Store (DS) Storage Engine during an Ericsson Centralized User Database (CUDB) system backup process or a DS Storage Engine backup process. For further information about the backup procedures, refer to CUDB Backup and Restore Procedures.
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Backup procedure fails. |
A backup procedure fails in a DS Storage Engine during a CUDB system backup process or a DS Storage Engine backup process. |
No connection to the Storage Engine Management Server. |
DS Storage Engine. |
No recent backup is available. |
|
Not possible to recover local information data from the Storage Engine. |
||||
|
Not possible to generate data backup for a single cluster due to insufficient space. |
||||
|
No connection to the remote CUDB node where the local backup is generated or operated. |
The alarm attributes are listed and explained in Table 2:
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
No |
|
Module |
STORAGE-ENGINE |
|
Error Code |
5 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raised. |
|
Resource ID |
.1.3.6.1.4.1.193.169.1.2.5. <ND> . <DG> |
|
Alarm Model Description |
Backup fault, Storage Engine. |
|
Alarm Active Description |
Storage Engine (DS-group # <DG> ): backup failed in node # <ND> . |
|
ITU Alarm Event Type |
processingErrorAlarm (4) |
|
ITU Alarm Probable Cause |
softwareProgramError (546) |
|
ITU Alarm Perceived Severity |
(4) - Major |
|
Originating Source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which alarms were raised. |
In Table 2, the indicated variables are as follows:
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide.
1.2 Prerequisites
This section provides information on the documents, tools and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following documents:"
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
If the alarm is raised, do the following:
Steps
- Check connections in the system.
-
Check the disk storage space in /home in the System Controllers
(SCs). If there is not enough space, remove previous backups. If not possible, in this
situation the
Operating System, Disk Usage Too Highalarm may be raised. For more information, refer to Operating System, Disk Usage Too High and follow the instructions provided therein. - Clear the alarm manually as described in CUDB Node Fault Management Configuration Guide.
- Run the backup again. For further information, refer to CUDB Backup and Restore Procedures.
- If the alarm is raised again, consult the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.
- If the alarm does not cease, contact the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.