1 Introduction
This instruction concerns alarm handling for the Storage Engine, Data Inconsistency between Replicas Repaired, DS alarm.
1.1 Alarm Description
This alarm is raised as a notification when the Data Repair procedure was invoked for the current Data Store (DS) master replica, and some of the inconsistencies between the current and the former master replicas have been successfully repaired.
The alarm is issued in the following situations:
The possible alarm causes and the corresponding fault reasons, fault locations, and impacts are described in Table 1.
|
Alarm Cause |
Description |
Fault Reason |
Fault Location |
Impact |
|---|---|---|---|---|
|
Some of the detected data inconsistencies between the current and former DS master replicas have been repaired. |
Data Repair was executed with the identified LDAP entries that might not have been correctly replicated between the former and current master replicas, and it managed to repair some of these entries. These LDAP entries are recorded in the repaired log. |
This is not a fault, but information about how the repair was performed. Information is provided in the repaired log as repair status. The meaning of the possible repair status values are as follows: |
Current and former DS master replicas. |
Some provisioning and traffic data has been repaired with a marginal chance for data loss in CUDB. |
The following are the consequences for the node if the alarm is not acted upon:
The alarm attributes are listed and explained in Table 2.
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
No |
|
Module |
STORAGE-ENGINE |
|
Error Code |
24 |
|
Time |
Date when the alarm was raised. |
|
Resource ID |
.1.3.6.1.4.1.193.169.1.2.24.<DG>.<TIMESTAMP> |
|
Alarm Model Description |
Data Inconsistency between Replicas Repaired, Storage Engine |
|
Alarm Active Description |
Storage Engine (DS-Group #DG): Data inconsistency between replicas repaired (task <TASKID>, blade <BLADE>) |
|
ITU Alarm Event Type |
processingErrorAlarm (4) |
|
ITU Alarm Probable Cause |
databaseInconsistency (160) |
|
ITU Alarm Perceived Severity |
(6) - Warning |
|
Originating Source IP |
Node ID where the alarm was raised. |
In Table 2, the indicated variables are as follows:
For further information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide.
For the interpretation of the repaired logs, refer to CUDB Automatic Handling of Network Isolation Output Description.
1.2 Prerequisites
This section provides information on the documents, tools, and conditions that apply to the procedure.
1.2.1 Documents
This instruction references the following documents:
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
When this alarm is raised, no particular action is required. The operator may proceed as follows to find the list of repaired entries and clear the alarm manually:
If the alarm does not cease, contact the next level of maintenance support. Further actions are outside the scope of this Operating Instruction.

Contents