1 Overview
This document provides the description and troubleshooting steps to take for the Security, Root Login Failed alarm.
1.1 Alarm Description
This alarm is raised when a user fails logging in to a Ericsson Centralized User Database (CUDB) node as root.
The alarm attributes are listed and explained in Table 1:
|
Attribute Name |
Attribute Value |
|---|---|
|
Auto Cease |
No |
|
Module |
SECURITY(11) |
|
Error Code |
2 |
|
Timestamp First |
Date and time when the alarm was raised for the first time. |
|
Repeated Counter |
Number which indicates how many times the alarm was raised. |
|
Timestamp Last |
Date and time of the most recent alarm raised. |
|
Resource ID |
.1.3.6.1.4.1.193.169.11.2.<IP> |
|
Alarm Model Description |
Root Login Failed, Security. |
|
Alarm Active Description |
Root Login Failed @<IP> |
|
ITU Alarm Event Type |
securityServiceOrMechanismViolation (10) |
|
ITU Alarm Probable Cause |
authenticationFailure (600) |
|
ITU Alarm Perceived Severity |
(6) – Warning |
|
Originating Source IP |
Node IP where the alarm was raised. |
|
Sequence Number |
Number which indicates the order in which alarms were raised. |
In Table 1, <IP> is the IP address of the server node.
For more information about attribute descriptions, refer to CUDB Node Fault Management Configuration Guide, Reference [1].
The possible causes of the alarm are as follows:
- A user has failed logging in to a CUDB node using root access.
1.2 Prerequisites
This section provides information on the documents, tools and conditions that apply to the procedure.
1.2.1 Documents
Refer to CUDB Node Fault Management Configuration Guide, Reference [1] for further information.
1.2.2 Tools
Not applicable.
1.2.3 Conditions
Not applicable.
2 Procedure
Perform the following steps:
- Make backup copies of the log files to preserve evidence of the (attempted) intrusion.
- Examine the security log file to determine the source of the intrusion. For more information about logging information in CUDB, refer to CUDB Node Logging Events, Reference [2].
- If the log file analysis indicates that an unauthorized operation was successful, seek further advice in order to secure the system again. For more information about security configuration in CUDB, refer to CUDB Security and Privacy Management, Reference [3].
- Once system security has been reestablished, refer to CUDB Node Fault Management Configuration Guide, Reference [1] to manually clear the alarm.
- Further actions are outside the scope of this Operating Instruction.
Glossary